E
If the platform should fail to lower, NEVER climb down the elevating
assembly.
Page 6
L
MERGENCY
OWERING
W A R N I N G
!
The Emergency Lowering Valve for the
X20N, X20W, and X26N is located at the
rear of the machine, above the charger.
The Emergency Lowering Valve for the
X31N is located at the rear of the
machine, to the left of the charger.
1. Open the Emergency Lowering Valve
by pulling and holding the knob.
2. To close, release the knob. The plat-
form will not elevate if the Emergency
Lowering Valve is open.
!
Figure 5: Emergency Lowering Valve Handle
Emergency Lowering Knob
Emergency Lowering Knob
X Series