Mastervolt MASS SINE ULTRA Installation Manual page 15

Multiple units
Table of Contents

Advertisement

9. Select Installer and enter the installer code.
10. Go to the Configuration tab and give the unit a logical name. For example, MSU L1, MSU L2 and MSU L3.
11. Return to the Configuration tab of the L1 unit. All settings are done here. However, if Mastervolt Lithium-Ion batteries are
connected, all events, like Stop Discharge for example, must be configured for ALL units separately.
12. In the Cluster pane, from the Phase System drop-down list, select Three Phase. You may need to maximize the
MasterAdjust window or scroll all the way to the right to see this.
13. From the Dev. Per phase drop-down list, select PER PHASE the number of units in parallel (Primary + Replica)! In our
example this is 1.
14. Click the Select devices button to be able to select the L2 and L3 units.
In the Phase L2 section, from the Phase master (Primary) drop-down list, select the L2 unit.
In the Phase L3 section, from the Phase master (Primary) drop-down list, select the L3 unit.
Mass Sine Ultra – Installation Manual Multiple Units
Three-phase configuration with MasterAdjust
15

Advertisement