Mastervolt Mass Sine Ultra 24/4000 User And Installation Manual

Mastervolt Mass Sine Ultra 24/4000 User And Installation Manual

Sine wave inverter
Table of Contents

Advertisement

Mass Sine Ultra
EN
NL
DE
FR
ES
IT
24/4000
SINE WAVE INVERTER
USER'S AND INSTALLATION MANUAL
Zie www.mastervolt.com/products/inverters-sine-wave/
Siehe www.mastervolt.com/products/inverters-sine-wave/
Voir www.mastervolt.com/products/inverters-sine-wave/
Vea www.mastervolt.com/products/inverters-sine-wave/
Vedere www.mastervolt.com/products/inverters-sine-wave/
10000010358/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mass Sine Ultra 24/4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mastervolt Mass Sine Ultra 24/4000

  • Page 1 Mass Sine Ultra 24/4000 SINE WAVE INVERTER USER’S AND INSTALLATION MANUAL Zie www.mastervolt.com/products/inverters-sine-wave/ Siehe www.mastervolt.com/products/inverters-sine-wave/ Voir www.mastervolt.com/products/inverters-sine-wave/ Vea www.mastervolt.com/products/inverters-sine-wave/ Vedere www.mastervolt.com/products/inverters-sine-wave/ 10000010358/01...
  • Page 2: Overview Mass Sine Ultra

    EN / Mass Sine Ultra OVERVIEW MASS SINE ULTRA Figure 0-1: Overview of the Mass Sine Ultra 1. Display with front switch 6. Fan (3x) 2. Battery negative 7. Ground stud 3. Battery positive 8. Sync connector (2x) 4. AC output 9.
  • Page 3: Table Of Contents

    EN / Mass Sine Ultra TABLE OF CONTENTS: OVERVIEW MASS SINE ULTRA ..............................2 GENERAL INFORMATION .............................. 5 Product description ............................. 5 Use of this manual .............................. 5 Validity of this manual............................5 Scope of warranty .............................. 5 Liability ................................5 Changes to the Mass Sine Ultra .........................
  • Page 4 EN / Mass Sine Ultra CONFIGURATION ................................. 20 Configuration via dip-switches .......................... 20 MasterBus configuration ........................... 21 COMMISSIONING, DECOMMISSIONING ........................23 Commissioning ..............................23 Decommissioning ............................. 23 Trouble shooting ............................... 23 TECHNICAL DATA ................................ 25 Specifications ..............................25 Dimensions ............................... 26 ORDERING INFORMATION ............................
  • Page 5: General Information

    Mass written permission of Mastervolt is prohibited. Sine Ultra other than by Mastervolt. The warranty is limited to the costs of repair and/or replacement of the product by This manual serves as a guideline for the safe and effective Mastervolt only.
  • Page 6: Safety Guidelines And Warnings

    Use of the Mass Sine Ultra other than mentioned in point 2 is considered to be inconsistent with the A procedure, circumstance, etc. which deserves intended purpose. Mastervolt does not hold itself liable extra attention. for any damage resulting from the above.
  • Page 7: Warning Regarding Life Support Applications

    In addition the manufacturer must system for electrical and electronic products. agree to indemnify and not hold Mastervolt responsible for Please act according to your local rules and do not dispose any claims arising from using Mass Sine Ultra parts for life of your old products with your normal household waste.
  • Page 8: Operation

    EN / Mass Sine Ultra 3 OPERATION Front panel See figure 3-3. The operation of the Mass Sine Ultra is The Mass Sine Ultra is a fully automatic inverter. It converts controlled by the main On/Off switch and displayed by a DC voltage to a pure AC sine wave voltage.
  • Page 9: Maintenance

    EN / Mass Sine Ultra 3.4.1 Output overload or short circuit 3.4.4 Dynamic DC input window In case of overload or short circuit, the Power bar top LED illuminates red and the output voltage of the Mass Sine Ultra is limited. The Mass Sine Ultra shuts down if this overload or short circuit lasts over 5 seconds.
  • Page 10: Daily Use, Masterbus Monitoring

    EN / Mass Sine Ultra Daily use, MasterBus monitoring The MasterBus Monitoring page offers the option to do your daily settings and it shows your settings from the Configuration page. The table below shows the Mass Sine Ultra monitoring values. The values with a default value are adjustable. Value Meaning Default...
  • Page 11: Installation

    EN / Mass Sine Ultra 4 INSTALLATION Wiring During installation and commissioning of the Mass Sine Ultra, the Safety Guidelines and Warnings are applicable at The wiring is connected inside the connection compartment. all times. See chapter 2 of this manual. If necessary, the wiring can be fed from the top to the bottom side of the cabinet along the back of the cabinet.
  • Page 12: Things You Need

    • Philips screw driver to open the connection area of the applied cable cross section. The fuse with fuse holder is Mass Sine Ultra. available from your local Mastervolt distributor or Customer Service Representative. Removal of the front lid 4.3.3...
  • Page 13: Mounting The Cabinet To A Surface

    EN / Mass Sine Ultra Wiring instructions WARNING Have installation work done by a licensed electrician only. Before connecting the wiring, make the AC distribution as well as the DC distribution voltage free. Move the main switch to the “Off”-position. CAUTION! Short circuiting or reversing polarity may lead to serious damage to the batteries, the Mass Sine...
  • Page 14: Installation Overview

    EN / Mass Sine Ultra Installation overview Figure 4-8: Installation overview for one Mass Sine Ultra CAUTION! Ensure correct polarities, cross sections and fuses for all wiring. An RCD according to local regulations must be connected to the output.
  • Page 15: Setting Up A Masterbus Network

    MasterBus network. For central monitoring and control of the connected devices Mastervolt offers different panels, like the full colour MasterView System panel. All monitoring panels can be used for monitoring, control and configuration of all connected MasterBus equipment.
  • Page 16: Installation Of Multiple Clustered Mass Sine Ultra's

    EN / Mass Sine Ultra 5 INSTALLATION OF MULTIPLE CLUSTERED MASS SINE ULTRA’S This installation instruction serves as a guideline for the safe General installation guidelines and effective installation of the Mass Sine Ultra in a multiple When using Mass Sine Ultra’s in a multiple configuration, the configuration, i.e.
  • Page 17: Parallel Configuration Diagram

    EN / Mass Sine Ultra Parallel configuration diagram Three phase configuration diagram Figure 5-3 shows a basic installation diagram of two Mass See figure 5-4. Three Mass Sine Ultra’s are shown in a three Sine Ultra’s in parallel. Both Mass Sine Ultra’s are supplying phase configuration.
  • Page 18: Configuration For Multiple Mass Sine Ultra Systems

    EN / Mass Sine Ultra Configuration for multiple Mass Sine Ultra systems The MasterBus name for a multi Mass Sine Ultra system is “Cluster“. A cluster can be a • single phase, • split phase or • 3-phase configuration, with one or more Mass Sine Ultra’s in parallel connection per phase.
  • Page 19: Masterbus Specific Alarms For Multi Mass Sine Ultra Systems

    EN / Mass Sine Ultra 5.10 MasterBus specific alarms for multi Mass Sine 5.12 Operation of multiple Mass Sine Ultra systems Ultra systems If connected in a more phase or parallel configuration, it is important which Mass Sine Ultra you selected as the master and which as the slave(s).
  • Page 20: Configuration

    EN / Mass Sine Ultra 6 CONFIGURATION The Mass Sine Ultra is provided with a group of DIP- switches to adjust the Mass Sine Ultra according to the specifications of the electrical installation, see figure 6-1. DIP-switch settings are 0 for default values. The Mass Sine Ultra also features the more sophisticated MasterBus configuration.
  • Page 21: Masterbus Configuration

    EN / Mass Sine Ultra MasterBus configuration Parameters below can be changed via the MasterBus network. See applicable user’s manuals for details. DIP switch settings overrule MasterBus settings. If DIP switches are not set to default, the corresponding MasterBus configuration is greyed out. Value Meaning Default...
  • Page 22 Install error Installation error around the Mass Sine Ultra, not inside the unit. Check all connections. System error Internal Mass Sine Ultra error. Contact your Mastervolt supplier. 6.2.2 List of event sources This is the Mass Sine Ultra list of event sources. These can initiate an event at another MasterBus connected device.
  • Page 23: Commissioning, Decommissioning

    Make sure you have the following information present if you Open the connection compartment of the Mass Sine have to contact your local Mastervolt Service Centre to solve Ultra; a problem: Check with a suitable voltage meter whether the input and the output of the Mass Sine Ultra are voltage free;...
  • Page 24 EN / Mass Sine Ultra 7.3.1 Trouble shooting table Illuminating LED’s MasterBus alarm Explanation / Possible cause What to do Normal operation and warnings None The Mass Sine Ultra is switched Switch on the Mass Sine Ultra by off manually. means of the main switch.
  • Page 25: Technical Data

    EN / Mass Sine Ultra 8 TECHNICAL DATA Specifications Mass Sine Ultra 24/4000 Article number 26024000 Inverter specifications Nominal battery voltage 24 V Inverter output voltage 230 V (±2%) Frequency 50/60 Hz (±0.005%) selectable Continuous power@Tamb=25˚C, cos phi = 1 4000 W Continuous power@Tamb=40˚C, cos phi = 1 4000 W...
  • Page 26: Dimensions

    EN / Mass Sine Ultra Dimensions Figure 8-1: Dimensions in mm...
  • Page 27: Ordering Information

    * Standardly included with the delivery of the Mass Sine Ultra Mastervolt can offer a wide range of products for your electrical installation, including automatic AC transfer switches, remote control panels and DC distribution kits. See our website www.mastervolt.com for an extensive overview of all our products.