The process must be activated before use. The subsequent restarting of the power source
switches back to the last active welding procedure.
Display
Press the welding procedure/ degaussing pushbutton.
The signal light "A" flashes.
Check the magnetic field on the workpiece with the magnetic field meter.
Increase the current with the rotary transducer until the magnetic field in the component decreases
towards "0".
If the field strength increases in the workpiece:
Switch off activgauss.
Change polarity by switching cables.
Switch on activgauss.
Increase the current with the rotary transducer until the magnetic field in the workpiece decreases to-
wards "0".
099-002129-EW501
15.10.2020
+
Setting/selection
Degaussing is activated.
Design and function
Figure 5-25
Figure 5-26
Degaussing