The process must be activated before use. The subsequent restarting of the power source
switches back to the last active welding procedure.
Display
•
Press the welding procedure/ degaussing pushbutton.
•
The signal light "A" flashes.
•
Check the magnetic field on the workpiece with the magnetic field meter.
•
Increase the current with the rotary transducer until the magnetic field in the component decreases
towards "0".
If the field strength increases in the workpiece:
•
Switch off activgauss.
•
Change polarity by switching cables.
•
Switch on activgauss.
•
Increase the current with the rotary transducer until the magnetic field in the workpiece decreases to-
wards "0".