Gear Unit With Torque Arm; Gear Unit With Gear­unit Swing; Gear Units With Cooling Coil; Gear Units With Add­on Air Oil­cooler - Siemens REDUREX Assembly And Operating Instructions Manual

Gear unit
Table of Contents

Advertisement

6.8

Gear unit with torque arm

Attaching the torque arm
The torque arm must be mounted stress­free.
Foundation type for fastening the torque arm, see item 6.3.1, "Foundation".
A detailed view of the gear unit can be obtained from the drawings in the gear­unit documentation.
6.9
Gear unit with gear­unit swing
Attach the support.
The support for the gear­unit swing base must be mounted free of stress.
Foundation type for fastening the torque arm, see item 6.3.1, "Foundation".
A detailed view of the gear unit can be obtained from the drawings in the gear­unit documentation.
6.10

Gear units with cooling coil

Before connecting the cooling coil the screw plugs must be removed from the connecting bushes.
Flush the cooling coil (in order to remove any contamination).
Connect the cooling­water in­ and outflow pipes (for exact position of the connections, see
dimensioned drawing).
Observe also item 5.7.2.
6.11
Gear units with add­on air oil­cooler
Connect pressure monitor electrically.
Connect contamination indicator of the double changeover filter (if fitted) electrically.
Connect the fan motor electrically.
6.12
Gear units with add‐on water oil­cooler
Before connecting the water oil­cooler remove the sockets from the cooling­water connections.
Flush the water oil­cooler (in order to remove any contamination).
Install the cooling­water in­ and outflow pipes (for flow direction and exact position of connections, see
dimensioned drawing).
Make sure when installing the piping that no forces, moments or vibrations act upon
the connections of the water oil­cooler.
Wire the pressure monitor electrically (in case of gear units with corresponding equipment only).
Observe also item 5.7.3.
For connecting dimensions, refer to the dimensioned drawing of the gear unit. The required
cooling water quantity and the max. permissible inlet temperature are given on the data sheet
and/or the list of equipment.
BA 5200 EN 08/2010