7.3.1.3 Interior­preservation procedure
Stop the gear unit.
Drain oil into a suitable container (see section 10, "Maintenance and Repair").
Unscrew breather screw.
Pour in the preservative agent through the hole of the breather screw and/or inspection cover up to the
top mark on the oil­sight glass.
For preservative agent see table 4 or 5 in item 4.4.1!
Screw the breather screw in and/or close the inspection­cover hole.
Start the gear unit and allow it to idle briefly.
Unscrew the oil­drain plug and/or open the oil­drain cock.
Drain preservative agent into a suitable container.
Dispose of preservative agent in accordance with regulations.
There is a risk of scalding from the hot preservative agent draining from the gear unit.
Wear protective gloves!
Screw the oil­drain plug in and/or close the oil­drain cock.
Replace breather screw with the screw plug.
Before re­starting the gear unit, replace the screw plug with the breather screw.
Observe the instructions in item 7.1.1.
7.3.2

Exterior preservation

7.3.2.1 Exterior­preservation procedure
Clean the surfaces.
For separation between the sealing lip of the shaft­sealing ring and the preservative agent, the
shaft should be brushed with grease in way of the sealing lip.
Apply preservative agent.
For preservative agent see table 6 in item 4.4.2!