8.

Operation

Observe the instructions in section 3, "Safety instructions", in section 9, "Faults, causes and remedy",
and in section 10, "Maintenance and repair"!
8.1

General

To achieve a satisfactory and trouble­free operation of the equipment, be certain to observe the operating
values specified in section 1, "Technical Data", as well as the information given in the operating instructions
of the oil­supply system.
During operation the gear unit must be monitored for:
Operating temperature
Oil pressure of the oil­supply system
Changes in gear noise
Possible oil leakage at the housing and shaft seals
8.2

Oil level

To check the oil level, stop operation of the gear unit.
Depending on the type the following oil levels apply when the motor has cooled down:
­ Middle of the oil­sight glass
­ Top mark on the oil dipstick.
If the oil is hot, the oil­level marks may be slightly exceeded. It must in no case be allowed to
fall below the mark. If necessary, top up to the correct level.
The oil level in the oil­supply system must be checked.
For this, the operating instructions of the oil­supply system must be observed!
8.3

Irregularities

The drive unit must be switched off at once,
Determine the cause of the fault, using table 12, "Faults, causes and remedy"
(see item 9.2).
Table 12, "Faults, causes and remedy", contains a list of possible faults, their causes
and suggested remedies.
If the cause cannot be found, a specialist from one of our customer­service centres
should be called in (see section 2).
The gear unit is designed for continuous operation at an
operating temperature of:
90 °C (mineral oil only)
The maximum permitted temperature is:
100 °C (mineral oil only)
(min. 0.5 bar)
if irregularities are found during the operation
or
if the pressure monitoring device in the oil­cooling system triggers
alarm (only with correspondingly equipped gear units).
BA 5200 EN 08/2010