Mono FG166-G11RH Setup And Operation page 13

Mxt rotary rack oven
Table of Contents

Advertisement

Gas connection
Mono MXTG ovens are supplied with a two-stage bespoke burner that is set-up prior to dispatch.
The burner is suitable for use with natural gas only. (See Specifications for other details).
Heat output
Gas pressure at connection point
50 kW
20.0 mbar
Warning
Burner installation and start-up should be carried out by an authorized technician.
Local regulations for gas installations must be followed.
Always check the nameplate for the gas type.
Do not use the burner with other gas types.
Repairs and maintenance to be carried out by an authorised service engineer.
Flue gas connection
Connection on oven:
Draft conditions:
Temperature:
Heat output
Flue gas temperature
50 kW
400 °C
Note: None of the flue gas ducts should slope downwards or be horizontal (if no flue gas fan is
installed). The slope must be upwards towards the chimney. Avoid too many sharp elbows.
Initial burning-off procedure
All ovens undergo the burn-off procedure in the factory before being dispatched.
Flue system
Flue connection:
Rack rotation
The rack hanger is driven by an electric motor situated on the mid left-hand side of the oven roof.
Power transmission to the rack-hanger's central drive shaft is by means of a single tensioned V-
belt that affords slippage of the transmission in the event of a blockage to rack rotation.
Rev. B21 21-05-21
Outside diameter
There must be a negative pressure of 1 to 5 mm WG in the
combustion chamber. If the pressure is higher than 0 mm WG in
service, a flue gas fan must be installed.
The gas exhaust flue must be capable of withstanding a temperature
of at least 400 °C.
See section - Dimensions.
MX Eco-touch Rotary Rack Gas Oven (FG166)
Gas flow with burner in operation
5.16 m³/h
130 mm
Ø
Flue gas quantity
150 m³/h
MONO EQUIPMENT
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fg166-g11lhMxt

Table of Contents