72
Commands
SET_TRIGGER_CMD
Set the trigger command to be executed when the trigger line is asserted
Description
Opcode, Length, Param1, Param2, Param3
Parameters
Opcode (unsigned eight-bit)--opcode of command to be executed
Parameter
Length --the length of the data portion
Description
Param1, Param2, Param3 (unsigned eight-bits)--first, second, and third parameter of the
selected command (number of parameters ranges from 0 to 3 depending of the selected
command)
Note that the default opcode is for reset (0x00
Command packet
OPCODE
Length
0x3F
0x02 to
1
0x0A
1.
The length is variable, depending on the selected command.
U8 Opcode, U8 Length, U8 Param1, U8 Param2, U8 Param3
Opcode (unsigned eight-bit)--Opcode of the command selected to be exe-
cuted as part of the trigger command (0x20 to 0x27)
Param1-Param8 (unsigned eight bit)--Data payload bytes specific to the
opcode specified.