JDS Uniphase SKB Series User Manual page 72

Fiberoptic switch module
Hide thumbs Also See for SKB Series:
Table of Contents

Advertisement

CONFIG?
Query the configuration of all logical switches
Description
NA
Parameters
NA
Parameter
Description
Command packet
OPCODE
Length
0x23
0x00
Response packet
OPCODE
Length
0xA3
0x04 to
1
0x0F
1.
The length is variable, depending on the number of switches in the module.
(1-4) * (U8 Sw_Id, U8 Sw_Type, U8 Max_In, U8 Max_Out)
Sw_Id (unsigned eight-bit)--Logical switch identification number (1 to 4)
Sw_Type (unsigned eight-bit)--Physical switch type (0:motor or 1:relay)
Max_In (unsigned eight-bit)--Maximum number of inputs of the switch (1 to 2)
Max_Out (unsigned eight-bit)--Maximum number of outputs of the switch (1
to 200)