CONFIG?
Query the configuration of all logical switches
Description
NA
Parameters
NA
Parameter
Description
Command packet
OPCODE
Length
0x23
0x00
Response packet
OPCODE
Length
0xA3
0x04 to
1
0x0F
1.
The length is variable, depending on the number of switches in the module.
(1-4) * (U8 Sw_Id, U8 Sw_Type, U8 Max_In, U8 Max_Out)
Sw_Id (unsigned eight-bit)--Logical switch identification number (1 to 4)
Sw_Type (unsigned eight-bit)--Physical switch type (0:motor or 1:relay)
Max_In (unsigned eight-bit)--Maximum number of inputs of the switch (1 to 2)
Max_Out (unsigned eight-bit)--Maximum number of outputs of the switch (1
to 200)
Parameters
Parameters
Commands
57