ALARM?
Query the alarm register value
Description
NA
Parameters
NA
Parameter
Description
Command packet
OPCODE
Length
0x03
0x00
Response packet
OPCODE
Length
0x83
0x02
Bit
15
Function
EPV
R/W
R
Initial value
0
EPV (EEPROM VERIFY FAIL, bit 15)--This bit indicates that the verify operation of an EEPROM
write failed. It is cleared when the AR is read.
OT (OVER TEMPERATURE, bit 14)--This bit indicates that ambient temperature of the module has
exceeded the high temperature threshold for a period of at least 10 seconds. It is cleared when the
temperature falls below the high temperature threshold.
UT (UNDER TEMPERATURE, bit 13)--This bit indicates that ambient temperature of the module has
dropped below the low temperature threshold for a period of at least 10 seconds. It is cleared when
the temperature falls below the high temperature threshold.
CFO (CONFIGURATION OVERFLOW, bit 12)--This bit indicates that user configuration commands
have been executed more than 50,000 times. This bit is not cleared when the configuration com-
mand counter exceeds 50,000. This bit can only be cleared at the JDS Uniphase factory.
U16 Alarm_reg
Alarm_reg (unsigned 16-bit)--Current binary value of the Alarm Register
(AR), as indicated in the following table
14
13
12
11
OT
UT
CFO
R
R
R
R
0
0
0
0
Parameters
Parameters
10
9
8
7
6
R
R
R
R
R
0
0
0
0
0
Commands
5
4
3
2
1
R
R
R
R
R
0
0
0
0
0
43
0
R
0