JDS Uniphase SKB Series User Manual page 62

Fiberoptic switch module
Hide thumbs Also See for SKB Series:
Table of Contents

Advertisement

TEMP?
Query temperature information. All temperature information is referenced in degrees
Description
Kelvin.
NA
Parameters
NA
Parameter
Description
Command packet
OPCODE
Length
0x06
0x00
Response packet
OPCODE
Length
0x86
0x06
U16 Hi_temp, U16 Low_temp, U16 Temp
Hi_temp (unsigned 16-bit)--Configured high temperature threshold (234 –
358 °K)
Low_temp (unsigned 16-bit)--Configured low temperature threshold (233 –
357 °K)
Temp (unsigned 16-bit)--Actual ambient temperature (233 – 358 °K)
Temperature (°C) = Temperature (°K) - 273
All temperature information is referenced in degrees Kelvin. Conversions are
as follows:
1 °C = 1 °K and 0 °C = 273 °K approximately
1 °F = 0.55 °K and 0 °F = 255.37 °K
Parameters