363-208-011
Cabling, Wiring, and Assembly
Step 1: Connect the cable assembly's P184 connector to the ARM shelf back-
plane connector J184.
Step 2: The prepared end of the cable assembly shall be wire wrapped to the
TS1 terminal block in accordance with Figure 3-20a.
Step 3: Add an additional black wire from terminal 7 to the ground lug terminal
on the left mounting screw.
18
19
20
1
2
3
4
O-3BK W-3BL
O
W-3O
S
W-3S
W
BL-3BK
Figure 3-20A. ATU/TS1 Wiring Interconnections
3-30
Issue 4 February 1997
:
NOTE
There are two black wires to be connected to the TS1 block
(terminals 7 and 24). The black wire to terminal 7 is the
grounded shield from the two shielded pairs of P184. The
black wire to terminal 24 is from P1A.
:
NOTE
Clock termination resistors and wiring connections to the TS1
block from the CO Clock and the CO Alarms will be made in
subsequent operations. Refer to those sections for details.
22
21
23
24
25
5
6
7
8
9
O
W-BL
BL
W-O
BK
BL
G-3BK
BK
BR-3BK
Refer to Figure 3-20B
26
28
29
27
G
W-3G
BR
W-3BR