AccuEnergy AcuRev 2100 Web Manual

AccuEnergy AcuRev 2100 Web Manual

Smart metering system

Advertisement

Quick Links

AcuRev 2100
Smart Metering System
Web Manual

Advertisement

Table of Contents
loading

Summary of Contents for AccuEnergy AcuRev 2100

  • Page 1 AcuRev 2100 Smart Metering System Web Manual...
  • Page 2 Copyright © 2021 V1.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written consent of Accuenergy. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 3 Please read this manual carefully before installation, operation and maintenance of the AcuRev 2100 Series Power Meter. The following symbols in this manual are used to provide warning of danger or risk during the installation and operation of the meters.
  • Page 4: Table Of Contents

    Chapter 6 - Web Interface Readings and Parameter Settings ......22 6.1 User Access Login .......................23 6.2 Dashboard ........................24 6.3 Metering web page .....................25 6.3.1 Basic Metering ....................26 6.3.2 Demand ......................27 6.3.3 Energy .......................28 6.3.4 Harmonics ......................29 6.3.5 I/O ........................30 6.4 Logs ..........................31 V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 5 7.9.4 Last Will & Testament ..................60 7.9.5 Topic and Parameter Selection ..............61 7.10 Remote Access ......................62 Chapter 8 - Management ..................64 8.1 Parameter Reset ......................65 8.2 Reboot Meter & Communications Module .............65 8.3 Change Password ......................66 8.4 SSH ..........................66 V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 6 Chapter - 10 Firmware ..................71 10.1 Module Firmware Update ..................72 10.1.1 Manual Update ....................73 10.1.2 Remote Update....................74 Chapter 11 - Config Management ..............77 11.1 Backup Configuration ....................79 11.2 Export/Apply Configuration ..................80 11.3 Import Configuration ....................81 V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 7: Chapter 1: Introduction

    AcuRev 2100 Series Power Meter: Web Manual Chapter 1: Introduction 1.1 Introduction to Ethernet...
  • Page 8: Introduction To Ethernet

    AcuRev 2100 Series Power Meter: Web Manual Chapter 1: Introduction The AcuRev 2100 meter provides a dual Ethernet and WiFi communication channel. Users will be able to use both Ethernet ports and WiFi simultaneously with different networks and data acquisition systems.
  • Page 9: Chapter 2: Functional Description Of The Ethernet Module

    Chapter 2: Functional Description AcuRev 2100 Series Power Meter: Web Manual Chapter 2: Functional Description of the Ethernet Module...
  • Page 10 Port is 502. The user-defined range is 2000~5999. The AcuRev 2100 grants users the ability to send emails based on a time interval or when there is a triggered event using the SMTP protocol. It can send mail from encrypted servers and servers that use different SMTP ports.
  • Page 11: Chapter 3: Installation Method

    Chapter 3: Appearance and Dimensions AcuRev 2100 Series Power Meter: Web Manual Chapter 3: Installation Method 3.1 Definition of RJ45...
  • Page 12: Definition Of Rj45

    AcuRev 2100 Series Power Meter: Web Manual Chapter 3: Appearance and Dimensions 3.1 Definition of RJ45 The AcuRev 2100 uses two standard RJ45 connectors to access the Ethernet network. The mechanical and electrical characteristics of the connector are consistent with the requirements of IEC 603-7.
  • Page 13: Chapter 4: Initializing The Ethernet Module

    Chapter 4: Installation AcuRev 2100 Series Power Meter: Web Manual Chapter 4: Initializing the Ethernet Module 4.1 Cable...
  • Page 14: Cable

    AcuRev 2100 Series Power Meter: Web Manual Chapter 4: Initializing the Ethernet module The default settings in the AcuRev 2100 meter series meter are as follows: Ethernet 1 (Static IP address) • IP Address (192.168.1.254) • Subnet Mask (255.255.255.0) •...
  • Page 15: Chapter 5: Connection Method

    Chapter 5: LED Description AcuRev 2100 Series Power Meter: Web Manual Chapter 5: Connection Method 5.1 Direct Connect to a Computer 5.2 Direct Connect to a Router/Switch 5.3 Connect through WiFi 5.4 Description of Modbus-TCP Protocol...
  • Page 16: Direct Connect To A Computer

    AcuRev 2100 Series Power Meter: Web Manual Chapter 5: Connection Method 5.1 Direct Connect to a Computer The AcuRev 2100 can be connected to a computer using a crossover cable (standard 568A). The AcuRev 2100 module supports Modbus-TCP and HTTPS Functions for this method of connection.
  • Page 17 Chapter 5: Connection Method • Once there, right-click on the local area connection icon and select properties. • Select the icon that says Internet Protocol Version 4 TCP/IP V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 18 AcuRev 2100 Series Power Meter: Web Manual • The Internet Protocol Version 4 (TCP/IP) Properties box will pop up • Click on ''Use the following IP address'' and enter an IP number so that the meter and computer are in the same local network range. For example, if the meter has an IP address of 192.168.1.254, then the computer must be assigned with an IP 192.168.1.xxx,...
  • Page 19: Direct Connect To A Router/Switch

    5.2 Direct Connect to a Router/Switch The AcuRev 2100 can be connected to a router or switch using a patch cable. The DHCP can be configured to Auto to have the router assign the meter with an IP address or the DHCP can be configured to Manual to set an IP address and network settings manually.
  • Page 20: Connect Through Wifi

    192.168.100.1. Ensure the device connecting to the AcuRev 2100 has DHCP enabled or it should be in the same subnet as the AcuRev 2100. The module will appear in the WiFi network as AcuRev 2100-WIFI-(serial number of the module) as the SSID or name of the wireless network.
  • Page 21: Modbus Application Header (Mba Header) Field

    Read Digital Input (DI) Status Obtain current status of Digital Input Read Data Obtain current binary value in one or more registers Place specific value into a series of consecutive Write Multiple Registers multiple registers V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 22: Data Field

    AcuRev 2100 Series Power Meter: Web Manual d. Data Field The data field is constructed using sets of two hexadecimal digits, in the range of 00 to FF. The data field of messages sent from a master to a slave contains additional information that the slave must use to take the action defined by the function code.
  • Page 23 Data start register hi: High byte of starting register address Data start register lo: Low byte of starting register address Data # of registers hi: High byte of number of registers Data # of registers lo: Low byte of number of registers V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 24: Chapter 6: Web Interface Readings And Parameter Settings

    AcuRev 2100 Series Power Meter: Web Manual Chapter 6: Web Interface Readings and Parameter Settings 6.1 User Access Login 6.2 Dashboard 6.3 Metering Web Page 6.4 Logs 6.5 About 6.6 Settings...
  • Page 25: User Access Login

    Web Interface Readings and Parameter Settings The AcuRev 2100 supports the HTTPS protocol to allow for the use of a web interface. The user will need to access the AcuRev 2100 interface to configure the module and use its functions.
  • Page 26: Dashboard

    The dashboard displays the basic metering page which allows users to view the real time readings such as voltage, current, power and power factor. This table is a summary of all user channels (circuits) connected to the AcuRev 2100 meter. V: 1.00 Revised: Jan 2021...
  • Page 27: Metering Web Page

    By clicking on "Select Channel" under the chart, the user will be able to see each input channel’s reading or three-phase User reading below. The parameters on this page are updated every 5 sec. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 28: Basic Metering

    ''I/O''. Each web page shows data from the AcuRev 2100 meter. 6.3.1 Basic Metering The Basic Metering webpage includes the data of real-time parameters for the AcuRev 2100 meter. This includes the Line Voltages, Phase Voltages, Current, Active, Reactive and Apparent Power, Power Factor, Frequency and Load type.
  • Page 29: Demand

    The demand table also includes the peak demand, the peak demand timestamp, and the demand prediction. This table provides the overall demand for all circuits connected to the AcuRev 2100 meter. User can select and view the demand for specific circuits by using the drop down menu option on the demand page.
  • Page 30: Energy

    AcuRev 2100 Series Power Meter: Web Manual 6.3.3 Energy The Power & Energy webpage shows the energy data for the AcuRev 2100 meter such as the Active, Reactive and Apparent energy that is consumed. The energy data is displayed as the total as well as per phase.
  • Page 31: Harmonics

    Select between voltage and current to view their respective harmonics. In the harmonic page users can view the THD, Voltage/Current unbalance factor, Even/Odd THD, Crest Factor and THFF readings. The parameters on this web page are updated every 15 sec. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 32: I/O

    AcuRev 2100 Series Power Meter: Web Manual 6.3.5 I/O There are 18 digital inputs for AcuRev 2100 series meter. Each digital input channel can be programmed as either a status indicator or a DI pulse input counter. Users can view the pulse count or digital status as well as reset the DI count from this page.
  • Page 33: Logs

    Click on the 'Logs' tab to visit the metering logs web pages. There are four kinds of logs that can be viewed, they are "Trend Log", "Data Log, "Alarm Log", and "Event Log". Each web page shows data from the AcuRev 2100 meter series meter. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 34: Trend Log

    AcuRev 2100 Series Power Meter: Web Manual 6.4.1 Trend Log The Trend Log web page includes the real-time and energy trend diagram. The real-time trend log diagram can be selected to show the following parameters phase voltage, line voltage, current, active power, reactive power, apparent power and power factor for each phase as well as the totals.
  • Page 35: Real-Time Parameters

    1 day 15 seconds Last 10 minutes 1 minute 15 seconds Today 1 hour 15 seconds Yesterday 1 hour 15 minutes Last 7 days 1 hour 1 day Custom Range Dependent on range specified V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 36: Energy

    AcuRev 2100 Series Power Meter: Web Manual 6.4.1.2 Energy Similarly, the energy parameters can be trended at different time intervals depending on the Time Frame selected. The table below displays the time intervals: Time Frame Time Intervals 15 seconds Last 10 minutes...
  • Page 37: Data Log

    'Delete Selected' button at the bottom of the page. Users will be prompted by a window asking to confirm the data log delete. NOTE: Deleting the data log is permanent, this cannot be undone once deleted. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 38: Alarm Log

    AcuRev 2100 Series Power Meter: Web Manual 6.4.3 Alarm Log The Alarm Log web page provides the user with a summary of the alarm events that have occurred with the meter. It will show the status of up to 16 alarm events indicating the alarm ID, status, parameter, value that exceeded or went below the threshold and the timestamp of the alarm event.
  • Page 39: Event Log

    Device Information page. This page provides users with information about the AcuRev 2100 series meter. The Device Information contains the model of the AcuRev 2100 meter, serial number, firmware version and the meter addresses. It also contains the serial number, firmware version, hardware version and the MAC addresses of the AcuRev 2100 web module.
  • Page 40: Settings

    AcuRev 2100 Series Power Meter: Web Manual 6.6 Settings 6.6.1 Meter The basic metering configurations needed to set up the meter can be applied from the web interface by clicking on the Settings and selecting the Meter. The meter settings page includes the following settings: •...
  • Page 41: Chapter 7: Communications

    Chapter 8: System Settings AcuRev 2100 Series Power Meter: Web Manual Chapter 7: Communications 7.1 Network 7.2 Email 7.3 Time/Date 7.4 Data Log 7.5 Post Channel 7.6 AcuCloud 7.7 BACnet/IP 7.8 SNMP 7.9 MQTT 7.10 Remote Access...
  • Page 42: Network

    AcuRev 2100 Series Power Meter: Web Manual Chapter 7: Communications The communication setting web page will allow the user to configure settings related to the Ethernet networks and the Wireless network. The functions and protocols that the AcuRev 2100 supports can be configured by selecting the corresponding tab such as Emails, Time/Date, Datalog, AcuCloud Post for communicating with the AcuCloud software, BACnet-IP, SNMP.
  • Page 43 Subnet Mask and Gateway if using this method. NOTE: The IP address of the Ethernet 2 can be found on page N12 of the NET Settings. The AcuRev 2100 meter protocol setting must be configured to AcuRev 2100 to view this from the meters NET settings.
  • Page 44 It can be configured as either Access Point (AP) or Station mode. • Access Point: Default configuration for AcuRev 2100. The AcuRev 2100 will act as a wireless access point and will allow other wireless devices to connect and access the AcuRev 2100.
  • Page 45 The user can also configure the DNS servers if the DHCP is set to Auto. NOTE: The WiFi IP address for the AcuRev 2100 will be in parameter N11 of the NET settings. •...
  • Page 46: Email

    After making any changes on the network settings page, click 'Save'. Users will be prompted to reboot the AcuRev 2100 immediately or later. If later is chosen the AcuRev 2100 will need to be rebooted from the 'Management' page in order for the settings to take effect.
  • Page 47 Start Time to Send Email: Select the date and time for when the emails should begin to send. • Click on the icon to configure the time and date. • Click on the icon in the bottom right to clear the time and date. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 48 AcuRev 2100 Series Power Meter: Web Manual • SMTP Server: Enter the URL of a valid SMTP server. I.E. mail.accuenergy.com or smtp. gmail.com • SMTP Port: Enter the port number associated with the SMTP server. • SMTP From: Enter a name or phrase which will appear to let you know who the mail is from.
  • Page 49 • System Event: Report of the SOE log. • DI: Report DI status/counters. The user will receive an email report in a CSV file attachment. The report will include the readings and/or the real time triggered event. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 50: Time/Date

    AcuRev 2100 Series Power Meter: Web Manual 7.3 Time/Date The device clock of the AcuRev 2100 meter series meter can be set through the web interface of the AcuRev 2100. The AcuRev 2100 supports NTP (Network Time Protocol) so that the module can update the meter's device clock by synchronizing with a time server.
  • Page 51: Data Log

    Click “Save” after configuring the time settings. Users will be prompted to reboot the AcuRev 2100 immediately or later. If later is chosen the AcuRev 2100 must be rebooted from the “Management” page in order for the settings to take effect.
  • Page 52 AcuRev 2100 Series Power Meter: Web Manual • Log Param Type: Users can select the type of parameters they wish to log into logger. Use the '>' button to add selected parameters into the data log and use the '<' button to remove selected parameters from the data log.
  • Page 53 By default "logger1" will be appended to the beginning of the log file. NOTE: The Post File Length and Local Log File Length must be less than or equal to the log interval selected. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 54: Post Channel

    The Clear Post Channel Logs button will allow users to clear the buffered files on the meter. The AcuRev 2100 can post data to a server at intervals of time ranging from 1 minute to 1 month. The settings for configuring the post channels to post the data can be found by clicking on Settings and then selecting the Communications tab.
  • Page 55 NOTE: The 'TEST Post Channel' button should only be utilized after clicking the 'Save' button otherwise a fail response will be observed. If a fail response occurs after clicking 'Save' confirm the network settings or credentials for the server. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 56: Acucloud

    AcuCloud will require the serial number of the AcuRev 2100 which will then provide a token that will be used to configure the AcuRev 2100 so it can send its data to AcuCloud. The settings for the AcuCloud post function can be found by clicking on the Settings tab and selecting Communications.
  • Page 57 Support. Click 'Save' after changing any settings. Users will be prompted to reboot the AcuRev 2100 immediately or later. If later is chosen the AcuRev 2100 must be rebooted from the 'Management' page for the settings to take effect. The AcuRev 2100 will post the data continuously every 5 minutes after the reboot.
  • Page 58: Bacnet/Ip

    AcuRev 2100 Series Power Meter: Web Manual 7.7 BACnet/IP The AcuRev 2100 supports the BACnet/IP protocol. The settings for the BACnet/IP protocol can be found on the web by clicking on the Settings tab and selecting Communications. Once on the communications page select BACnet/IP to access the settings to configure the AcuRev 2100 to communicate with a BACnet client.
  • Page 59: Snmp

    Click 'Save' after changing any settings. Users will be prompted to reboot the AcuRev 2100 immediately or later. If later is chosen the AcuRev 2100 must be rebooted from the 'Management' page in order for the settings to take effect.
  • Page 60: Mqtt

    Broker Port: Enter the port number for the MQTT Broker • Client ID: Enter the Client ID for the AcuRev 2100; must be a unique ID number • Keep Alive: The client communicates a time interval in seconds to the broker, “Keep- Alive”...
  • Page 61: Mqtt Authentication

    Chapter 7: Communications 7.9.2 MQTT Authentication The User Credential tab allows users to configure a “User Name” and “Password” authentication if the broker is able to support it. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 62: Mqtt Encryption

    On this page, users will be able to upload the required certificate and key files. 7.9.4 Last Will & Testament The AcuRev 2100 supports Last Will and Testament messages via the MQTT protocol. These settings can be configured under the Last Will & Testament tab.
  • Page 63: Topic And Parameter Selection

    Users will need to specify the data they want to publish under the parameter selection box. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 64: Remote Access

    AcuRev 2100 Series Power Meter: Web Manual 7.10 Remote Access The AcuRev 2100 supports a remote access function that allows users to access the meters web interface remotely from anywhere using a special url. Users will have full functionality and access to all meter readings and settings with this function.
  • Page 65 Remote Access Information: Lets users know if the remote access status is online or offline. • Remote Access URL: The URL used to access the meters web server remotely. This URL can be copied and shared with all users that require remote access. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 66: Chapter 8: Management

    AcuRev 2100 Series Power Meter: Web Manual Chapter 8: Management 8.1 Parameter Reset 8.2 Reboot Meter & Communications Module 8.3 Change Password 8.4 SSH 8.5 Debug Diagnostic 8.6 Diagnostic File...
  • Page 67: Parameter Reset

    This not only resets the communication module, it also performs a soft reboot on the AcuRev 2100 meter. V: 1.00 Revised: Jan 2021...
  • Page 68: Change Password

    6 characters or more. 8.4 SSH The AcuRev 2100 supports the SSH which can be enabled to allow users to remotely log into the meter using the SSH protocol. When enabled the status will show 'On', when disabled the status will show 'Off'.
  • Page 69: Diagnostic File

    NOTE: The system performance may be affected by enabling the debug logs. 8.6 Diagnostic File The is a diagnostic file on the AcuRev 2100 that users can download which can be used to analyze the modules diagnostics. NOTE: Please send the diagnostic file to Accuenergy Technical Support (support@accuenergy.com) for analysis.
  • Page 70: Chapter 9: Network Diagnostic

    AcuRev 2100 Series Power Meter: Web Manual Chapter 9: Network Diagnostic 9.1 Network Status 9.2 Host Lookup 9.3 Connection Test...
  • Page 71: Network Status

    Chapter 9: Network Diagnostic Chapter 9: Network Diagnostic 9.1 Network Status The Network Diagnostic page can be used to monitor the network status of the module. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 72: Host Lookup

    AcuRev 2100 Series Power Meter: Web Manual 9.2 Host Lookup In the Host Lookup tab, users can utilize the 'ping' function to test the reach-ability to other networks. Users can also use the ping6 function to ping an IPv6 address.
  • Page 73: Chapter 10: Firmware

    Chapter 9: Protocols AcuRev 2100 Series Power Meter: Web Manual Chapter 10: Firmware 10.1 Module Firmware Update...
  • Page 74: Module Firmware Update

    There is an Auto Firmware Update feature available also, this allows users to update the module automatically without manually going into the webserver and performing the update. NOTE: Users can also contact Accuenergy Technical Support for the latest firmware. V: 1.00 Revised: Jan 2021...
  • Page 75: Manual Update

    Chapter 10: Firmware 10.1.1 Manual Update Select and upload the AcuRev 2100 firmware file, it is a .a2up file extension. Once the upload was successfully uploaded you will see the following page confirming that the file was uploaded. Click 'Process' to begin the update.
  • Page 76: Remote Update

    AcuRev 2100 Series Power Meter: Web Manual The meter will reboot itself after the update. Login to the web interface of AcuRev 2100 after the reboot is complete, and go to the 'About' page to check if the module firmware version is updated.
  • Page 77 Chapter 10: Firmware If there is an update available users can proceed to download the firmware. Once the download is complete the updating process will begin. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 78 AcuRev 2100 Series Power Meter: Web Manual When the firmware update is complete, the module will reboot. The rebooting process will take 1-2 minutes to complete. After the module reboots, users will be able to log back into the web interface. When logged in click on the 'About' tab located on the top right corner of the web page to view the 'Device Information' page.
  • Page 79: Chapter 11: Config Management

    Chapter 9: Protocols AcuRev 2100 Series Power Meter: Web Manual Chapter 11: Config Management 11.1 Backup Configuration 11.2 Export/Apply Configuration 11.3 Import Configuration...
  • Page 80 AcuRev 2100 Series Power Meter: Web Manual Chapter 11: Config Management The AcuRev 2100 has a configuration management page that allows users to save all web settings with the exception of certain settings into a configuration file. This is useful if users have more than one meter that needs to be programmed with the same settings, and eliminates any error when trying to configure another AcuRev 2100.
  • Page 81: Backup Configuration

    The Config Management page can be accessed by clicking on the Settings tab and selecting Config Management. 11.1 Backup Configuration Users can create a backup of the current configurations on the AcuRev 2100 interface. • Backup Current Configuration Description: Enter in a description for the backup configuration file.
  • Page 82: Export/Apply Configuration

    Users can remove any of the configuration files from the list at any time by selecting Delete. 11.2 Export/Apply Configuration Users can export the configuration file and use it on other AcuRev 2100 units. The file is downloaded as a .ehm file. V: 1.00 Revised: Jan 2021...
  • Page 83: Import Configuration

    Management page in order for the settings to take effect on the device. 11.3 Import Configuration Import Configuration: Users can import a configuration file (.conf.ehm file format) to the AcuRev 2100. V: 1.00 Revised: Jan 2021 www.accuenergy.com...
  • Page 84 AcuRev 2100 Series Power Meter: Web Manual Click on Import to upload the configuration file to the AcuRev 2100. The newly imported file will now appear in the List of Local Configurations NOTE: Users cannot import a file that already exists on the local configurations, when the list already contains 10 config files, and cannot import a config file that has been exported from an AcuRev 2100 with a higher firmware version.
  • Page 85 INT: +1-416-497-4100 FAX: +1-416-497-4130 2 Lansing Square, Suite 700 E: marketing@accuenergy.com Toronto, ON M2J 4P8, Canada ACCUENERGY SOUTH AFRICA (PTY) LTD TF: +27 (0) 87 802 6136 Castle Walk Corporate Park, Block B, Cnr. Nossob & Swakop Street Erasmuskloof, Pretoria, 0181...