BACnet for Acuvim II Series
Power Meter
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for AccuEnergy Acuvim II

  • Page 1 BACnet for Acuvim II Series Power Meter User's Manual...
  • Page 2 Copyright © 2018 V2.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written consent of Accuenergy.
  • Page 3 The information contained in this document is believed to be accurate at the time of publica- tion, however, Accuenergy assumes no responsibility for any errors which may appear here and reserves the right to make changes without notice. Please ask the local representative for latest product specifications before ordering.
  • Page 4: Table Of Contents

    Chapter 1: BACnet Overview ………………………………………………3 Chapter 2: Introduction ………………………………………………………3 Chapter 3: About BACnet Protocol …………………………………………3 Chapter 4: Using the Acuvim II Series Power Meter’s BACnet Protocol ………………………………………… 4 Chapter 5: Using The BACnet Module (AXM-BACnet) ………………… 5 5.1 Installation Method ………………………………………………………………………5...
  • Page 5: Chapter 1: Bacnet Overview

    BACnet IP protocol supports 106 objects which lets you track up 78 measurements and 28 IO parameters. The Acuvim II Series Power Meter supports native BACnet/IP that lets it act as a BACnet server in any BACnet application. The Acuvim II Series Power Meter’s BACnet IP also comes with a Web interface that allows users to configure the BACnet related parameters and read measurements by using a standard browser.
  • Page 6: Chapter 4: Using The Acuvim Ii Series Power Meter's Bacnet Protocol

    Present_Value, watt, tot (value in watts) For more detailed information, visit the BACnet website at www.bacnet.org. 4. Using the Acuvim II Series Power Meter’s BACnet Protocol Serial and Ethernet Versions There are different serial and Ethernet based-versions of BACnet. The most common serial version is called BACnet MS/TP while the dominant Ethernet version is BACnet/IP.
  • Page 7: Chapter 5: Using The Bacnet Module (Axm-Bacnet)

    Speed 9600 kbit/s,19200 kbit/s, 38400 kbit/s and 76800 kbit/s Max. Station 127 MS/TP masters Data Up to 480 bytes per telegram frame 5. Using The BACnet Module (AXM-BACnet) 5.1 Installation Method Figure 5-1 V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 8: Definition Of Rj45 Interface And 485 Interface

    BACnet for Acuvim II Series Power Meter The BACnet module is linked to the Acuvim II meter by a communication plug. It can also be linked to other extended modules like IO modules. 1. Insert the installation clips to the counterpart of the meter, and then press the BACnet module lightly, so linking is established.
  • Page 9: Initializing The Bacnet Modules

    IP Address (192.168.1.254);Subnet Mask (255.255.255.0);Gateway (192.168.1.1); DNS1 (8.8.8.8); DNS2 (8.8.4.4); The Acuvim II will need to be configured in order to communicate with the AXM-BIP. The following process shows how to configure BACnet module settings by using the keys on the display: •...
  • Page 10 BACnet for Acuvim II Series Power Meter Figure 5-5 Figure 5-6 • Once in the system settings menu, the initial page is S01 ADDR, the meters RS485 address page. Press the "P" key to go to the S03 BPS2 page. The baud rate should be at 38400.
  • Page 11 • Press "V/A" key to modify; ‘NO’ should begin to flash • Press "P" key to change ‘NO’ to ‘RESET’. • Press "V/A" key to reset the module. ‘NO’ will be displayed on the screen and the AXM-BIP module settings should now take effect. V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 12: Bacnet Ms/Tp Module (Axm-Bms)

    AXM-BMS Module's default settings are as follows: MAC Addr(0); BACnet Bps(9600); Max Info Pram(1) The Acuvim II will need to be configured in order to communicate with the AXM-BMS. The following process shows how to configure BACnet module settings by using the keys on the display: •...
  • Page 13 The first page of the BACnet related settings is the BACnet MSTP address, which is defaulted to 0. Users can define the range of the address from 0-127. After setting the BACnet MSTP address, press the "V/A" key to confirm the setting. Figure 5-10 V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 14 BACnet for Acuvim II Series Power Meter • Press the "P" key to move to the second page for the BACnet module baud rate. • Press the "V/A" key to enter edit mode to select the desired baud rate using the "P" or "E"...
  • Page 15 Select Reset and this will load the module with the modified settings. Press the "V/A" key to confirm. Figure 5-13 • After configuring the AXM-BMS settings, press “H” key and “V/ A” key simultaneously to return to menu selecting mode. V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 16 6. BACnet Objects 6.1 AXM-BIP Reading Objects The AXM-BIP module for the Acuvim II series power meter supports 78 predefined objects based on the meters real-time measurement parameters. There is no programming or map- ping necessary to use the BACnet objects. The object's name easily identifies the measure- ment they contain.
  • Page 17: Chapter 6: Bacnet Objects

    Phase A Import Active Energy Float Analog Input Phase A Export Active Energy Float Analog Input Phase B Export Active Energy Float Analog Input Phase B Export Active Energy Float Analog Input Phase C Import Active Energy Float V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 18 BACnet for Acuvim II Series Power Meter Instance Object Type Name Object Data Type Units Analog Input Phase C Export Active Energy Float Analog Input Phase A Import Reactive Energy Float kvarh Analog Input Phase A Export Reactive Energy Float...
  • Page 19 Analog Input IO22-AI3 Float mA/Volts 1004 Analog Input IO22-AI4 Float mA/Volts 1005 Analog Input IO31-AI1 Float mA/Volts 1006 Analog Input IO31-AI2 Float mA/Volts 1007 Analog Input IO32-AI3 Float mA/Volts 1008 Analog Input IO32-AI4 Float mA/Volts V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 20 Analog Input IO12-DI6-Counter 2021 Analog Input IO22-DI1-Counter 2022 Analog Input IO22-DI2-Counter 2023 Analog Input IO22-DI3-Counter 2024 Analog Input IO22-DI4-Counter 2025 Analog Input IO32-DI1-Counter 2026 Analog Input IO32-DI2-Counter 2027 Analog Input IO32-DI3-Counter 2028 Analog Input IO32-DI4-Counter V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 21: Axm-Bms Reading Objects

    Chapter 6: BACnet Objects 6.2 AXM-BMS Reading Objects The AXM-BMS on the Acuvim II Series Power Meter's BACnet IP has 56 predefined objects of electrical measurements. No programming or mapping is necessary to use the BACnet objects. The object’s names easily identify the measurements they contain. All of the objects, with the exception of Modbus Meter and POLL_DELAY are AI (analog input) Object type.
  • Page 22 BACnet for Acuvim II Series Power Meter Object Data Object Type Instance Name Value Parameter Type Analog Value P_dema Float ADI34 P Demand Analog Value Q_dema Float ADI35 Q Demand Analog Value S_dema Float ADI36 S Demand Analog Value Ia_Demand...
  • Page 23: Chapter 7: Axm-Bip Through The Web Server

    • Open an Internet browser and enter the IP address of the meter. • Login in with 'Admin' access. NOTE: The default password for the Admin user access is 'admin'. • Click on 'Settings' and select 'Communications'. V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 24 BACnet for Acuvim II Series Power Meter • Select the 'BACnet-IP' tab to configure the settings related to BACnet-IP protocol. • Under "BACnet Enabled" select 'Yes' to enable the BACnet protocol. V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 25 • Enter BACnet Port of the BBMD in "BBMD Port" • Enter a value between 5-1440 min in the "Time To Live" for how often the foreign device will register in the BBMD's foreign device table. V: 2.0 Revised: June 2018 www.accuenergy.com...
  • Page 26: Bacnet Protocol Implementation Conformity Statement

    BACnet for Acuvim II Series Power Meter • Click 'Save' to save all settings to the module. The module will require a reboot in order for the settings to take effect. • Click on 'Settings' and select 'Management'. • Click on the 'Reset' button on the "Reset Communications Module" option.