Summary of Contents for YSI WE KNOW ProOBOD

  • Page 1 USE R MA N UA L...
  • Page 2: Table Of Contents

    C O N T E N T S Warranty ......................i Introduction ....................... 1 Getting Started ....................2 Unpacking the OBOD Probe ............. 2 ProOBOD Operation ..................4 Connecting Probe/Cable Assembly to Instrument ......4 Configuring the ProODO Instrument ..........4 Powering the Stirrer ................
  • Page 3: Warranty

    Within the warranty period, YSI will repair or replace, at its sole discretion, free of charge, any product that YSI determines to be covered by this warranty.
  • Page 4: Introduction

    I N T R O D U C T I O N Thank you for purchasing the YSI Professional Optical Biochemical Oxygen Demand (ProOBOD) probe. The ProOBOD is designed for use with a YSI ProODO® instrument. The probe will not work with any other YSI instrument.
  • Page 5: Getting Started

    Carefully unpack the instrument and accessories and inspect for damage. Compare received parts with items on the packing list. If any parts or materials are damaged or missing, contact YSI Customer Service at 800-897-4151 (+1 937 767-7241) or the authorized YSI distributor from whom the instrument was...
  • Page 6: Proobod Operation

    Coefficients, the sensor cap serial # will be updated automatically based on your proof. entries. The Temperature Coefficient should not be modified unless instructed by YSI Technical Support. For additional information about the ProODO’s menus and operation, please refer to the ProODO User Manual.
  • Page 7: Temperature

    It is not necessary to calibrate in both % and mg/L or ppm. temperatUre Calibrating in % will simultaneously calibrate All ProOBOD probes have built-in temperature sensors. Temperature calibration mg/L and ppm and vice versa. is not required nor is it available. To set the units, press the Probe key on the ProODO instrument and select Display.
  • Page 8: Maintenance And Storage

    UpDating instrUment anD prOBe firmware this manual for instructions on how to recondition the sensor cap. The instrument and probe firmware can be updated via www.ysi.com/software. There you will find the new firmware files and instructions on how to update the Refer to Figure 3 below when following the instructions for replacing the cap.
  • Page 9: Sensor Maintenance - Temperature

    Clean the stir paddle and then reinstall it on the probe by pushing it straight If you continue to get an error message after several entry into place. attempts, contact YSI Technical Support for assistance. Store the sensor in a BOD bottle with a small amount of water (approximately 40 ml).
  • Page 10: Sensor Storage

    Moisten the sponge in the clear protective plastic cap that was originally provided carefully remove the o-ring and contact YSI Technical Support to obtain a new with the probe with clean water. Place the clear cap over the sensor with the o-ring and/or gasket.
  • Page 11: Restore Default Calibration Values

    For the most recent specifications and for specifications Probe Temp under range Temperature is under -5°C or reading on the ProODO instrument, please visit www.ysi.com. erroneously. Check cable connection Probe (ProObOD probe and cable assembly) and ensure temperature sensor is clean.