3 DCC Blocks
3.11

Torque Proving

Symbol
p22160
H1_boEnableStartPulse
p22161
H1_boEnableTorqueProving
p22162
H1_rSpeedController_I_Component (r1482)
p22163
H1_rActualCurrent (r68.1)
p22164
H1_rMinimumTorque (%)
p22165
H1_rNoLoadTorque (%)
p22166
H1_boDeactivateTorqueProvingAtNoLoad
p22167
H1_rMonitoringFaultDelayTime (ms)
p22168
H1_ResetTorque
p22169
H1_rTorqueBuildingSpeedSetpointLimit (%)
p22170
H1_rTorqueBuildingSpeedSetpointRamptime (%)
p22280
H2_boEnableStartPulse
p22281
H2_boEnableTorqueProving
p22282
H2_rSpeedController_I_Component (r1482)
p22283
H2_rActualCurrent (r68.1)
p22284
H2_rMinimumTorque (%)
p22285
H2_rNoLoadTorque (%)
p22286
H2_boDeactivateTorqueProvingAtNoLoad
p22287
H2_rMonitoringFaultDelayTime (ms)
p22288
H2_ResetTorque
p22289
H2_rTorqueBuildingSpeedSetpointLimit (%)
p22290
H2_rTorqueBuildingSpeedSetpointRamptime (%)
Brief description
The TorqueProving block builds the actual torque sufficient enough to release the
brakes, and monitors that enough actual torque is developed in the motor before
releasing the brake.
Mode of operation
After enabling this function, when the brakes are applied, the TorqueProving block
retentively stores the value of actual torque. Next time the brake opening sequence
begins, the currently available actual torque is compared with the retentively stored
actual torque during previous braking and with a pre-parameterized minimum
required actual torque value. Until the current actual torque is greater than both
values (stored actual torque value during previous braking and minimum torque
value), the TorqueProving block will not release the brake opening permit. Once
the current actual torque is greater than or equal to the torque to be proven, then
the brake opening permit from the TorqueProving block is given, but the final brake
release command is still determined within SINAMICS brake control.
The TorqueProving block can be used with (recommended) or without StartPulse.
This block can be used for either one or two hoist operation. For two hoist
operation, torque sharing and speed synchronized operations are possible.
If p21602 CommonSignals_boEnable_Mode_H1+2 is selected (meaning two hoists
are present in the system configuration) torque proving can be enabled on either
hoist 1, hoist 2, or both. If torque proving is enabled for both hoists, the brakes will
not release until both hoists have proven sufficient torque.
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
TorqueProving
H1_boOut_SP_EnableBrakeStoreValue (p22070)
H1_rOut_SP_TorqueValueRetain (p22071)
H1_boOut_SP_CommandOpenBrake (p22072)
H1_boOut_SP_CommandCloseBrake (p22073)
H1_rOut_SpeedControllerI-ComponentAtPreviousBraking (%)
H1_rOut_ActualTorqueAtPreviousBraking (%)
H1_boOut_TorqueProvingMonitoringFault
H1_rOut_AdditionalSpeedSetpoint (p1160)
H2_boOut_SP_EnableBrakeStoreValue (p22070)
H2_rOut_SP_TorqueValueRetain (p22071)
H2_boOut_SP_CommandOpenBrake (p22072)
H2_boOut_SP_CommandCloseBrake (p22073)
H2_rOut_SpeedControllerI-ComponentAtPreviousBraking (%)
H2_rOut_ActualTorqueAtPreviousBraking (%)
H2_boOut_TorqueProvingMonitoringFault
H2_rOut_AdditionalSpeedSetpoint (p1160)
V1.2,
09/2019
H1_rOut_ActualTorque (%)
H1_rOut_TorqueToBeProven (%)
H1_boOut_TorqueProvingOk (%)
H1_boOut_CloseBrake (p1224.2)
H1_boOut_NoLoadConditionDetected
H1_rOut_ActualTorqueAtFault (%)
H2_rOut_ActualTorque (%)
H2_rOut_TorqueToBeProven (%)
H2_boOut_TorqueProvingOk (%)
H2_boOut_CloseBrake (p1224.2)
H2_boOut_NoLoadConditionDetected
H2_rOut_ActualTorqueAtFault (%)
r22190
r22191
r22192
r22193
r22194
r22195
r22196
r22197
r22198
r22199
r22200
r22201
r22202
r22450
r22310
r22311
r22312
r22313
r22314
r22315
r22316
r22317
r22318
r22319
r22320
r22321
r22322
r22451