Setting Tip
Table 3-10-1
Brake Test data set setting tip
SINAMICS
Name
parameter
number
p492
Maximum
speed
difference
per
sampling
cycle
p640
Current limit
p1082
Maximum
speed
p1520
CO: Torque
limit upper
p1521
CO: Torque
limit lower
p1530
Power limit
motoring
Power limit
p1531
regenerative
Motor
p2175
blocked
speed
threshold
p2177
Motor
blocked
delay time
Motor
p2178
stalled delay
time
NOTE
The above table indicates only suggested parameters and values, individual
parameters and values must be determined based on user's application.
NOTE
If SINAMICS faults occur during the brake test, adjust all parameters mentioned
in table 3-9-1.
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
Connection
Data type
type
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
IN
REAL
V1.2,
09/2019
Meaning
Sets the maximum
Set to more than speed
permissible speed
setpoint in order to
difference within the
develop required torque
current controller
sampling time
Set to about 225% of
Sets the current limit
operational data set value
Sets the highest
Increase from default
possible speed
value, but this value is
entirely dependent on the
design data of the motor,
and must be determined
for specific application
Sets the fixed, upper
Set to approximatley
torque limit
225% of operational data
set value
Sets the fixed, lower
Set to approximatley
torque limit
225% of operational data
set value
Sets the power limit
Set to approximatley
when motoring
225% of operational data
set value
Sets the
Set to approximatley
regenerative power
225% of operational data
limit
set value
Sets the speed
Increase from default
threshold for the
value, but this value is
message ''Motor
entirely dependent on the
blocked'' (BO:
design data of the motor,
r2198.6)
and must be determined
for specific application
Sets the delay time
Set a value larger than
for the message
p22013 BrakeTestOK_
''Motor blocked''
DelayTime (ms)
(BO: r2198.6)
Sets the delay time
Set to approximatley
for the message
200% of operational data
''Motor stalled'' (BO:
set value
r2198.7)
Reccomended Value