Dcc Block Commonsignals - Siemens SINAMICS S120 Manual

Drive-based technology dcc addon description
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3 DCC Blocks
3.3

DCC Block CommonSignals

Symbol
p21600
boEnable_Mode_H1
p21601
boEnable_Mode_H2
p21602
boEnable_Mode_H1+2
p21603
H1_boFeedback_ReadyToSwitchOn (r899.0)
p21604
H1_boFeedback_Ready (r899.1)
p21605
H1_boFeedback_OperationEnable (r899.2)
p21606
H1_boFeedback_SwitchOnInhibit (r899.6)
p21607
H1_boFeedback_PulseEnable (r899.11)
p21608
H1_boFeedback_commandBrakeOpen (r899.12)
p21609
H1_boFeedback_commandBrakeClose (r899.13)
p21610
H1_boFeedback_DriveStationary (r1229.7)
p21611
H1_boFeedback_Fault_Sinamics (r2139.3)
p21612
H1_boFeedback_AxisMoved (r2199.1)
p21613
H1_boFeedback_RampComplete (r2199.5)
p21614
H1_boFeedback_Nact>=0 (r2197.3)
p21615
H1_boExternalInterlockOff1
p21616
H2_boFeedback_ReadyToSwitchOn (r899.0)
p21617
H2_boFeedback_Ready (r899.1)
p21618
H2_boFeedback_OperationEnable (r899.2)
p21619
H2_boFeedback_SwitchOnInhibit (r899.6)
p21620
H2_boFeedback_PulseEnable (r899.11)
p21621
H2_boFeedback_commandBrakeOpen (r899.12)
p21622
H2_boFeedback_commandBrakeClose (r899.13)
p21623
H2_boFeedback_DriveStationary (r1229.7)
p21624
H2_boFeedback_Fault_Sinamics (r2139.3)
p21625
H2_boFeedback_AxisMoved (r2199.1)
p21626
H2_boFeedback_RampComplete (r2199.5)
p21627
H2_boFeedback_Nact>=0 (r2197.3)
p21628
H2_boExternalInterlockOff1
p21630
boFaultAcknowledge
Brief description
The CommonSignals block takes SINAMICS status word signals as inputs and
internally reads the status from every block and finally outputs the application fault
or alarm for SINAMICS.
NOTE
This block must be executed for the proper operation of the ExtendedCraneDCC
and must be configured properly.
Connections
Table 3-3-1
SINAMICS
Name
parameter
number
p21600
boEnable_Mode_H1
p21601
boEnable_Mode_H2
p21602
boEnable_Mode_H1+2
p21603
H1_boFeedback_
ReadyToSwitchOn (r899.0)
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
CommonSignals
Connection
type
assignment
IN
IN
IN
IN
V1.2,
09/2019
H1_boOut_ExternalFault (p2106)
H1_boOut_ExternalAlarm (p2112)
H2_boOut_ExternalFault (p2106)
H2_boOut_ExternalAlarm (p2112)
boOut_Fault_IllegalMode
Default
Data type
0
BOOL
0
BOOL
0
BOOL
0
BOOL
p21631
p21632
p21633
p21634
p21635
Meaning
Enables hoist 1 mode
Enables hoist 2 mode
Enables hoist 1 plus 2
mode
Connect hoist 1 r899.0
(Ready for switching on)
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents