e. For proper cooling and airflow, neatly fold and secure the excess
signal cable length above the CPU. Use a tie wrap or cable clip to
secure the cables.
.
f. At the front of the server, slide the drive into the bay until it clicks into
place.
g. Secure the drive carrier to the front of the server with the screws you
removed earlier.
Tighten the screws firmly.
h. Ensure that the cable connections at the hard drive end are secure.
Note: Connectors could be dislodged when you slide the hard drive
all the way inside the bay.
.
i. Reinstall the fans (if removed).
For instructions, see "To install a front system fan" on page 168.
j. Reinstall the upper fan holder foam (if removed).
For instructions, see "To replace the upper fan holder foam" on page
160.
Part 5: 703t Server Maintenance and Diagnostics
Maintaining the AMI MegaRAID Elite 1600 RAID system
CAUTION
Risk of equipment damage
Ensure that any cables in the proximity of the fans are
kept away from the fans. If a cable is caught in a fan, the
fan will break.
WARNING
Risk of data loss, corruption, or system malfunction
If the hard drive cable connections are loose, data loss,
data corruption, or system malfunction can occur.