Download Print this page

Philio PAD02 Quick Start Manual page 4

Z-wave smart dimmer socket

Advertisement

Restore
4
1
dimmer state
3-1 Dimmer level report mode :
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_
REPORT to the nodes of group1. The default setting is Enable the function.
3-2 LED indication mode :
3-2-1 Show dimmer State:When dimmer is on, LED is on. When dimmer is off,
LED is off. The default setting is Show dimmer State.
3-2-2 Show Night mode:When dimmer is on, LED is off. When dimmer is off, LED
is on.
3-2-3 One flash mode : When dimmer on/off state changes, LED will light on one
second and then off.
3-3 Restore dimmer state :
Whenever the AC power return from lost, PAD02 will restore the switch state which
could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last
dimmer state.
4. Firmware update over the air (OTA)
PAD02 is based on 500 series SoC and supports Firmware Update Command
Class, it can receives the updated firmware image sent by controller via the
Z-wave RF media. It is a helpful and convenient way to improve some function if
needed.
5. Command Classes
The Switch supports Command Classes including...
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
0-2
1
0 : Dimmer off
1 : Last dimmer state
2 : Dimmer on
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_MULTILEVEL_V2
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
Screw lampholder Type:
Since the socket type for each country in Europe varies, refer to the outline for each
socket suited for each country as follows:
EU TYPE: PAD02-1
4

Advertisement

loading