Download Print this page

Philio PAD02 Quick Start Manual page 3

Z-wave smart dimmer socket

Advertisement

Basic Set Command:[Command Class Basic, Basic Set, Value = 0 ]: the light
attached to the dimmer turns off.
1-3 MULTILEVEL SWITCH GET
Upon receipt of the following commands from a Z-Wave Controller, the dimmer will
report its dim level to the node inquired.
Multilevel Switch Get Command: [Command Class Multilevel Switch, Multilevel
Switch Get]
Multilevel Switch Report Command:
Report OFF: [Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0 ]
Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
= 1~99 ]
1-2 Multilevel Switch SET
Upon receipt of the following commands from a Z-Wave Controller, the dimmer
will be set to the dim level.
Multilevel Switch Set Command: [Command Class Multilevel Switch, Multilevel
Switch Set, Value = 1~99, Duration = 0~255 ]: the light attached to the dimmer
turns on.
Multilevel Switch Set Command: [Command Class Multilevel Switch, Multilevel
Switch Set, Value = 0, Duration = 0~255 ]: the light attached to the dimmer turns
off.
2. Z-Wave's Group
2-1 Group1 Lifeline :
(Maximum 5 nodes)
The dimmer can be set to send reports to associated Z-Wave devices. It supports
one association group with one node support for Grouping 1. For group 1, the dimmer
will report ALARM_REPORT 、DEVICE_RESET_LOCALLY_NOTIFICATION
MULTILEVEL_SWITCH_REPORT.
2-1-1 Overload alarm report
When PAD02 detects overload, it will send Alarm Report to group 1 node. After
detecting overload state and sending this alarm report, PAD02 will turn off the light
automatically and lockout the On/Off button. The only thing to do is unplug PAD02
and reduce the load. Then re-plug PAD02 and it will work again.
The content of Alarm Report
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type =
0x08, Alarm Level = 0xFF]
2-1-2 Device reset locally notification :
When PAD02 is reset manually, it will send a DEVICE_RESET_LOCALLY_
NOTIFICATION to the nodes of group 1.
2-1-3 Multilevel switch report :
Whenever the level of PAD02 is changed , it will send a MULTILEVEL_SWITCH_
REPORT to the nodes of group 1.
Multilevel Switch Report Command:
Report OFF: [Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0 ]
Report ON:[Command Class Multilevel Switch, Multilevel Switch Report, Value
= 1~99 ]
2-2 Group 2 Control_key1 : (Maximum 5 nodes)
When the On/Off status changes or the dim level is achieved manually, it will send
BASIC_SET command to group 2 nodes to make them unanimous.
Basic Set Command:
Dimmer Off:[Command Class Basic, Basic Set, Value = 0 ]
Dimmer On:[Command Class Basic, Basic Set, Value = 1~99 ]
3. Z-Wave's Configuration
and
Configuration
Function
Parameter
Dimmer
1
Level Report
mode
LED
2
indication
mode
3
Size
Value
Unit
Default
(Byte)
1
0-1
1
1
1-3
1
Description
0 : Disable
1 : Enable
1 : Show dimmer state
2 : Show night mode
3 : One flash mode

Advertisement

loading