Stoppages - Siemens SIMOTICS SD 1LE5 Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

Operation

8.6 Stoppages

8.6
Stoppages
The stoppage is a shutdown for a period of time, during which the machine is stopped but
remains at the location of use.
Under normal ambient conditions, e.g. the stationary machine is not exposed to any
vibration, no increased level of corrosion, ... then the following measures are required.
Longer non-operational periods
• For longer non-operational periods (> 1 month), either operate the machine or at least
turn the rotor regularly, approximately once per month.
• If attached, remove the rotor shipping brace before you turn the rotor.
• Carefully comply with the information in Section "Switching on" before switching on to
recommission the motor.
NOTICE
Restricted motor function
If not used for longer periods of time, material damage or complete motor failure can occur.
If the motor is out of service for a period of more than 12 months, then environmental
effects can damage the motor.
• Apply suitable corrosion protection, preservation, packaging and drying measures.
Switching on the anti-condensation heating, if available
Only switch on the anti-condensation heating after the motor has been switched off. Comply
with the data stamped on the plate of the anti-condensation heating, if available.
Taking the machine out of service
Detailed information on how to take the machine out of service is provided in Chapter
Preparing for use (Page 27).
Lubricating before recommissioning
NOTICE
Dry running bearings
Bearings can be damaged if they do not have sufficient grease.
• Re-grease the bearings if they have been out of service for more than one year. The shaft
• More information can be found in Chapter Rolling bearings (Page 101).
86
must rotate so that the grease can be distributed in the bearings. Follow the instructions
on the lubricant plate.
1LE5, 1PC4 shaft height 315/355
Operating Instructions, 10/2020, A5E41454666A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics sd 1pc4

Table of Contents