OIL SYSTEM SCHEMATIC
STARTER
The starter is relay-controlled to minimize the length of heavy cable
required to carry the high amperage of the starter circuit. The starter is
actuated by a key type, momentary-on switch located on the left of the
control column. To energize the starter circuit, rotate the ignition switch
to the START position and hold. Before starting it is necessary that the
subpanel battery switch be turned on.