BEFORE YOU BEGIN: Power must be cut before wiring, setting the Dip Switches or making any wiring changes
DESCRIPTION & CONNECTIONS
Switch 1
ON
Drive with encoder sensor
OFF
Drive without encoder sensor
Switch 2
(Requires Switch 1 ON)
ON
Activates synchronization S1 and S2
OFF Deactivates synchronization S1 and S2
Switch 3
ON
5.5 A max. per output
OFF
3 A max. per output
Switch 4
ON
Activates the temperature sensor
OFF Deactivates the temperature sensor
Switch 5
ON
Close in the event of wind
OFF
Open in the event of wind
Input Power Supply
A
-
24 Vdc power supply
input (SELV)
B
+
Drive Power
S1
-
BLU
C
24 Vdc - 3A/5.5A
+
D
Selected via Dip Switch 3
BRN
Encoder Signal
YEL
E
Encoder Requires Dip
Switch 1 ON
GRN
F
Encoder Power
-
BLK
G
+
RED
H
F
Rain Sensor
O
Contact
Dry contact input
P
Common
+
Q
Power supply output:
-
24 VDC 300 mA
R
DESCRIPTIONS OF CIRCUIT BOARD INDICATOR LIGHTS
The LED ashes every 4 seconds: Circuit board waiting.
The LED ashes rapidly: Command in progress.
The red LED light remains illuminated for 5 seconds: Current consumption threshold has
been exceeded or circuit board has heated up too much during an output command.
The red LED ashes: drive synchronisation fault.
The orange LED remains illuminated for several seconds: Backing-up the memory.
The orange LED ashes rapidly: Movement of a drive not permitted by a sensor action.
The orange LED remains illuminated: The rain threshold has been
exceeded.
The orange LED ashes rapidly: protection still in progress for 15
minutes ater the threshold last being exceeded.
Copyright © Somfy SAS 12/2019
Pergola Tilt RTS Control Box
Connection Quick Start Guide
External
antenna
T
-
+
Contact
S2
Rain
Q
R
O P
Sensor
-
BLU
M
Power
+
N
BRN
Output
Contact
-
S1 +
K
YEL
C
D
E F
GRN
L
+
I
RED
-
BLK
J
Status
Fault
Rain
S
OFF
OFF
OFF
OFF
OFF
POWER SUPPLY
-
+
A
B
-
-
+
S2 +
+
-
OUTPUT Vdc
OUTPUT Vdc
I J K L
G H
M
E
N
F
+
The orange LED remains illuminated: the ice threshold has been
exceeded. The Control is locked.
The orange LED ashes rapidly: protection still in progress for 15
minutes after the latest threshold is exceeded. Sensors locked out.
P-0036
External antenna
S
Signal Conductor
T
GND Shielding braid
Status
Fault
Wind
Rain
Temperature
1
PROG
button
DIP
Switch 1
ON
2
Switch 2
ON
Switch 3
ON
Switch 4
ON
Switch 5
ON
3
Power
supply
input
Drive
S2
Drive
S1
Wind
The orange LED remains illuminated: Wind
threshold has been exceeded.
The orange LED ashes rapidly: protection still
in progress for 15 minutes ater the threshold
last being exceeded.
Temperature
4
T
S
Need help?
Do you have a question about the Pergola and is the answer not in the manual?