BEFORE YOU BEGIN: Power must be cut before wiring or making any wiring changes
DESCRIPTION & CONNECTIONS
Switch 1
ON
Drive with coder sensor
OFF
Drive without coder sensor
Switch 2
(only if switch 1 is set to ON)
ON
Activates synchronization S1 and S2
OFF
Deactivates synchronization S1 and S2
Switch 3
ON
5.5 A max. per output
OFF
3 A max. per output
Switch 4
ON
Activates the temperature sensor
OFF
Deactivates the temperature sensor
Switch 5
ON
Closing in the event of wind
OFF
Opening in the event of wind
Power Supply Input
A
-
24 Vdc power supply input (SELV)
B
+
Drive output 1
Blue
C
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
Brown
D
+
Drive output 2
Blue
E
-
24 Vdc - 3A/5.5A drive: Maximum
current according to switch 3
Brown
F
+
Rain Sensor
O
Contact
Dry contact input
P
Common
Q
-
Power supply output:
R
24 Vdc/- 300 mA
+

DESCRIPTIONS OF CIRCUIT BOARD INDICATOR LIGHTS

The LED flashes every 4 seconds: Circuit board waiting.
The LED flashes rapidly: Command in progress.
The red LED light remains illuminated for 5 seconds: Current consumption threshold has
been exceeded or circuit board has heated up too much during an output command.
The red LED flashes: drive synchronisation fault.
The orange LED remains illuminated for several seconds: Backing-up the memory.
The orange LED flashes rapidly: Movement of a drive not permitted by a sensor action.
The orange LED remains illuminated: The rain threshold has been
exceeded.
The orange LED flashes rapidly: protection still in progress for 15
minutes after the threshold last being exceeded.
Copyright © Somfy SAS 7/2019
Pergola Tilt RTS Control Box
Connection Quick Start Guide
External
antenna
T
Output
R
Q
O P
Power
supply
Rain
sensor
-
+
-
+
OUTPUT Vdc
C
D
OUTPUT Vdc
-
+
-
S1
OUTPUT Vdc
-
+
-
+
S1
OUTPUT Vdc
Status
Fault
Rain
(1) (2)
S
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
A
B
E
F
POWER SUPPLY
POWER SUPPLY
+
-
+
-
S2 +
OUTPUT Vdc
-
+
-
S2 +
OUTPUT Vdc
The orange LED remains illuminated: the ice threshold has been
exceeded.
The orange LED flashes rapidly: protection still in progress for 15
minutes after the latest threshold is exceeded.
P-0036
External antenna
S
Signal
T
GND
Status
Fault
Wind
Rain
1
Temperature
PROG
button.
Switch 1
2
Switch 2
Switch 3
Switch 4
Switch 5
3
Power
supply
input
Drive
output S2
Drive
output S1
Wind
The orange LED remains illuminated: Wind
threshold has been exceeded.
The orange LED flashes rapidly: protection still
in progress for 15 minutes after the threshold
last being exceeded.
Temperature
(1) (2)
Conductor
Shielding braid
4
T
S
(1)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pergola and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOMFY Pergola

  • Page 1 Pergola Tilt RTS Control Box Connection Quick Start Guide BEFORE YOU BEGIN: Power must be cut before wiring or making any wiring changes DESCRIPTION & CONNECTIONS External antenna External Switch 1 antenna Signal Conductor Drive with coder sensor Shielding braid...
  • Page 2 Check the motor power plug to ensure it is fully inserted and the retainer caps screws are in flush. 1. INITIATE PROGRAMMING 2. CHECK THE DIRECTION OF OPERATION 2.1 Press the UP button to confirm the pergola opens. 1.1 Press & hold the PROG button on the circuit board until both S1 and S2 LEDs flash.

Table of Contents