3. Turn the knob to 1013 hPa (29.91 inHg) to complete the proce-
dure. Observe the units and values next to QNH. They changed
from hPa to inHg and vice versa.
3.3

Toggle Illumination Knob

1020
1035
This section applies only to instruments without push/rotate knob.
If the external illumination knob does not work – screen does not re-
act on the knob, try the following procedure. This procedure enables
remote illumination knob if it was not enabled or disables illumina-
tion knob, if it was enabled.
1. Turn QNH until it shows 1020 hPa (30.12 inHg) and wait for
about three seconds for a short cyan line to appear on top of
LCD display.
2. Quickly turn the knob to indicate 1035 hPa (30.56 inHg). A
moment later a longer cyan line appears.
3. Turn the knob to 1013 hPa (29.91 inHg) to complete the pro-
cedure.
4. Finally, you need to turn off Indu Combo and then back on in
order to activate the change.
4
Maintenance & Repair
No special maintenance is required.
The instrument has no serviceable parts inside. In the case of mal-
function, it must be sent to factory for a repair.