5. DIAGNOSTIC TEST OPERATION
6. Select the END button to perform the test. Then, make sure the key code layout is correct.
NOTE:
This test can be performed continuously after the POS K/B setting. (Rebooting the POS terminal
is not required.)
(2) Error code
Result
Error Code
0
1
-1
POS Keyboard Device Control Function Error Code Table
Value
-1
Parameter error (driver)
-2
NAK receive response
-3
Time out error
-4
IO busy error
-7
Parameter error (function)
-8
Device file open error
-9
Another error
-10
Keyboard setting file open error
-11
Keyboard setting file format error
-12
Keyboard setting file selection error
-13
Data check error
(3) Corrective action
Error
The setting file could not
be opened.
<< Preliminary version >>
Error Code Ex
0
0
1
See POS Keyboard Device Control
Function Error Code Table.
Error
• Specify a keyboard setting file. Or the selected file is unreadable.
0
None of operation was performed.
0
The POS K/B setting was performed
correctly.
The setting file could not be opened.
The setting file could not be opened.
Descriptions of the keyboard setting file are incorrect.
The selected file is not a DAT file (.dat).
The data written into the EEPROM causes an error. Retry
to perform this operation.
Cause & Measure
5- 22
5.4 Serviceman Diagnostic Test Program
Remarks
Remarks
EO18-12017