6.10. Command set automation
6.10.1. General Information
The command
set automation
device.
Required:
name — the name of the connected device for which the automation rules are configured;
Available options:
name — the new name of the connected device for which automation rules are config-
ured;
device-type — type of supported miner (device for crypto currency production);
description — additional description of the device up to 254 characters;
outputs — outlets numbers, where the device is connected (one or more) in the format
"[0-9]" or "[0-9], [0-9]..."
check-interval-seconds — check interval in seconds;
inter-restart-interval-seconds — the protection interval between reboots in seconds;
test — test configuration for Automation.
Display help:
set automation ?
The return is:
set automation device-name - device name to set configured automation for
Type 'help' to get suggestions
Example a query help with device name:
set automation device-name DEVICE-2 ?
The return is:
PCM Commands description:
set automation device-name DEVICE-2
check-interval-seconds
default
description
is intended for editing the properties of automation for selected
- interval between automation tests in
seconds
- set default values for parameters
check-interval-seconds and
inter-restart-interval-seconds
- description of device, 1 to 254
characters
6. Command Reference of RPCM CLI