6.9. Command set output

This command serves to control the outlet by setting various parameters.
Help ask:
set output 0 ?
The return is:
RPCM Commands description:
set output 0-9 description
set output 0-9 name
set output 0-9 off
set output 0-9 on
set output 0-9 overcurrent
alarm
turn off
set output 0-9 overvoltage
turn off
disabled
limit volts 0-65534
set output 0-9 recognition
off
on
set output 0-9 recover turn on
after overvoltage
disabled
seconds 0-65534
set output 0-9 survival priority - set output turn off on input overload
set output 0-9 help
Type 'help' to get suggestions
6.9.1 Command set output description
This command set an outlet description.
Example of use:
set output 0 description "Outlet 0"
The return is:
Description for Output 0 has been updated
Type 'help' to get suggestions
- set output description
- set output name
- turn off output number 0-9
- turn on output number 0-9
- tune overcurrent limits
for alarming
for turning off
- set output overvoltage turn off
configuration
disable it
set limit in volts
- set output 0-9 recognition state
to off
to on
- set recover turn on after overvoltage
configuration
disable recover turn on
set stabilization delay before turning on
priority
- show this help
6. Command Reference of RPCM CLI