4. Installation on Emerson Fans Having a
Modular Switch Housing with Center Screw
4.1
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or Main Fuse Box before attempting to
install the Ceiling Fan Light Fixture.
4.2
Remove the Switch Housing from the Cover Plate by
removing the Three Screws around the side of the
Switch Housing (Figure 3).
Retain the Three Screws for future use in Step 4.9.
4.3
Disconnect the Motor Connector from the Switch
Housing Connector (Figure 4).
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
SWITCH HOUSING
SCREWS (3)
Figure 3
MOTOR
CONNECTOR
SWITCH
HOUSING
Figure 4
Please contact 1-800-654-3545 for further assistance
5
WARNING
COVER
PLATE
SWITCH
HOUSING
SWITCH
HOUSING
CONNECTOR
emersonfans.com
U.L. Model No.: LK65
COVER
PLATE