Installing Dau; Installation Kit - ABB MACHsense-R Instruction Manual

Table of Contents

Advertisement

Document type
Instruction manual for MACHsense-R - MSR1600
6

Installing DAU

6.1

Installation kit

The MACHsense-R kit contains the following:
The recommended way of installing vibration sensors is to glue the mounting pads into their correct
position on the motor.
·
Recommended glue: Loctite AA326
·
Recommended Activator: Loctite SF7649
·
Recommended cleaner Loctite 7061
Note: Mounting glue is not included in the MACHsense-R package.
Safety Data sheet are available at the Loctite website http://www.henkel-adhesives.com.
Always have the Safety Data sheet available and follow the instructions carefully.
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without
express authority is strictly forbidden.
© Copyright 2017 ABB
Item description
DAU
Accelerometers (four)
Mounting pad (four)
Cable (four, 10 m each)
Installation guidelines
PROPRIETARY AND SECRET INFORMATION
Document identity
Revision
1MZB100400
A
Page(s)
14(31)