4.5 Installing the sensor

When installing the sensor, observe the following points:
— Installation in the pipe component or welding adapter is
only possible if the sensor data matches the measuring
point specifications.
— The sensor may be sealed only by using the O-ring supplied
in the scope of delivery. The O-ring must be placed in the
designated groove on the sensor connection flange.
— The measuring elements may not be damaged when
inserting the sensor into the pipe component.
— If you are using an integrated changing device, you must
check that the changing device is in the disassembly
position before releasing the mounting screws.
4.5.1

Wafer type design and welding adapter

Fig. 14:
Installing a sensor (example)
1 Sensor 2 Flange screws 3 O-Ring 4 Sensor connection flange
5 Centering pin 6 Washers and nuts
Installing the sensor:
1.
Place the supplied O-ring in the groove of the sensor
connection flange.
2.
Carefully slide the sensor into the pipe component. Observe
correct alignment to the centering pin in the process
3.
Fasten the sensor to the sensor connection flange using
screws. Tighten the flange screws simultaneously by
applying the required torque (torque for supplied screws,
non-lubricated, without use of spring washers: 87 Nm).