Technical Specifications; Power Supply Specifications; Failsafe Alarm Relay Specifications; Copper Ethernet Port Specifications - Siemens SIMATIC NET RUGGEDCOM i800 Installation Manual

Rugged ethernet
Hide thumbs Also See for SIMATIC NET RUGGEDCOM i800:
Table of Contents

Advertisement

Technical Specifications

This section provides important technical specifications related to the device and
available modules.
5.1

Power Supply Specifications

a
(T) denotes a time-delay fuse.
5.2

Failsafe Alarm Relay Specifications

Note
The following specifications are for Class-2 circuits only.
Maximum Switching Voltage
5.3

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM i800.
a
Auto-Negotiating
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
RUGGEDCOM i800
Installation Manual, 01/2021, C79000-G8976-1002-06
Power
Minimum Input
Supply Type
24 VDC
9 VDC
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Speed
Connector
10/100Base-TX
Maximum Input
32 VDC
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
Cable
a
Duplex
Type
> Category
RJ45
FDX/HDX
Internal
a
Fuse Rating
3A (T)
Isolation
1500 V
rms
Wiring
Maximum
b
c
Standard
Distance
TIA/EIA
100 m
5
T568A/B
(328 ft)
5
Maximum Power
Consumption
9 W
for 1 minute
e
Isolation
d
1.5 kV
19