Mounting the Device to a Panel
For panel installations, the RUGGEDCOM M2100 can be equipped with panel
adapters pre-installed on each side of the chassis. The adapters allow the device to
be attached to a panel using screws.
RUGGEDCOM M2100
Installation Manual, 04/2021, C79000-G8976-1042-17
Make sure the rack mount adapters are installed on the correct side of the
chassis.
To make the modules and ports accessible, install the rack mount adapters
at the rear of the chassis
To make the management ports and LEDs accessible, install the rack mount
adapters at the front of the chassis
Note
The chassis features multiple mounting holes, allowing the rack mount adapters
to be installed up to 25 mm (1 in) from the face of the device.
1
3
Rear
1
Front
2
Rack Mount Adapter
3
Figure 2.1
Rack Mount Adapters
If required, install adapters on the opposite side of the device to protect from
vibrations.
Insert the device into the rack.
Secure the adapters to the rack using the supplied hardware.
Installing the Device
2.3.2 Mounting the Device to a Panel
2
3
11