System Errors

Following System Error Message are recorded.
SP XX > 22 mA
Cause:
Solution:
SP XX < 3 mA
Cause:
Solution:
GC Error:
Cause:
Solution:
Maintenance:
Cause:
Solution:
3.2

Stage Status

Display the actual stages exceeded in the sequence they happen. The sensor points are over laid where a stage
has been exceeded. Changes are not possible in this menu.
SP 01
S1 S2
Symbol
Description
Sensor Point
SP 01
(SP) Point No.
SX
Stage Status
3.3

Relay Status

Display the actual status of each relay. Manual operation of the relays.
R 01
OFF
Symbol
Description
R 01
Relay No. 01
OFF
Status Relay
Polygard® is a registered trademark of MSR
Customer Services (858) 578-7887 & (888) GO INTEC
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | relevantsolutions.com/inteccontrols
12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | relevantsolutions.com/inteccontrols
INTEC Controls, 12700 Stowe Dr., Suite 100, Poway, CA 92064
INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
Specifications subject to change without notice. | USA 131119 | Page 9 of 30
Specifications subject to change without notice. | USA 160104 | Page 9 of 30
Specifications subject to change without notice. | USA 200211 | Page 9 of 30
Current signal at analog Input XX > 22 mA.
Short-circuit at analog Input or Transmitter not calibrated, Transmitter defective.
Check cable to Transmitter, Make Calibration, Change the Transmitter.
Current signal to analog Input XX < 3 mA.
Wire break at analog Input or Transmitter not calibrated, Transmitter defective.
Check cable to Transmitter, Make Calibration, Change the Transmitter.
Internal Communication Error I/O Board to LCD Board.
Internal Error.
Change the Controller.
System maintenance is necessary.
Maintenance date exceeded.
Perform maintenance.
Function
S1 = Stage 1 ON
S2 = Stage 2 ON
S3 = Stage 3 ON
S4 = Stage 4 ON
S5 = Stage 5 ON
Setting
Function
Status
Select Relay No.
OFF
ON
OFF
Manual OFF
Manual ON
Fax (858) 578-4633 & (888) FX INTEC
= Relay Off (Not Activated by Stage Setpoint)
= Relay On (Activated by Stage Setpoint)
= Relay manual Off
= Relay manual On