Radius Configuration - Cisco FM1000 Gateway Installation And Configuration Manual

Ultra-reliable wireless backhaul
Hide thumbs Also See for FM1000 Gateway:
Table of Contents

Advertisement

is fluidmesh. To show the password as it is being typed, check
the Show SNMP v3 password: check-box.
4.
Choose the correct authentication protocol from the SNMP v3
authentication proto: drop-down. The available options are
MD5 and SHA.
5.
If needed, choose the correct encryption protocol from the SNMP
v3 encryption: drop-down. The available options are No
Encryption, DES (Data Encryption Standard) and AES
(Advanced Encryption Standard).
6.
To change the current encryption passphrase, enter a new
passphrase in the SNMP v3 encryption passphrase: field. The
default encryption passphrase is fluidmesh. To show the
passphrase as it is being typed, check the Show SNMP v3
encryption passphrase: check-box.
7.
SNMP traps can be enabled for significant system-related events.
If needed, enable SNMP event traps by checking the Enable
SNMP event trap: check-box, and enter the name of the network
management station (NMS) host in the NMS hostname: field.
8.
You can also configure the unit to send SNMP traps at defined
periodic intervals. If needed, enable periodic SNMP traps by
checking the Enable SNMP periodic trap: check-box, and enter
the name of the network management station (NMS) host in the
NMS hostname: field.
9.
Save the SNMP settings by clicking the Save button.
Alternatively, clear the settings by clicking the Reset button.

6.7.6. RADIUS configuration

The RADIUS window contains the controls to provide centralized
authentication, authorization, and accounting management using the
remote authentication dial-in user service (RADIUS) networking protocol.
© 2021 Cisco and/or its affiliates. All rights reserved.
Device configuration using the configurator interface
IMPORTANT
The same SNMP authentication protocol must be set
for all Fluidmesh units in the wireless network.
IMPORTANT
The same encryption protocol must be set for all
Fluidmesh units in the wireless network.
IMPORTANT
The NMS host to which traps are sent must have an
SNMP agent configured to collect v2c traps.
Page 80 of 138