Toshiba GD-1060 Service Handbook page 72

Hide thumbs Also See for GD-1060:
Table of Contents

Advertisement

• UAD 3
Bit
7
Allowable gap during dial tone detection (PABX):
6
00: Off
01: 70 msec.
10: 160 msec.
11: 240 msec.
5
Method to detect dial tone and line current (PABX):
4
000:
BZT (DTC/LCC)
3
001:
LCC 5 sec.
010:
DTC only
011:
Undefined
100:
DTC (USA)
101:
LCC 3 sec.
110:
Undefined
111:
No Check
2
Maximum waiting time for dial tone (PABX):
1
000:
20 sec.
0
001:
10 sec.
010:
8 sec.
011:
15 sec.
100:
3.3 sec.
101:
Undefined
110:
Undefined
111:
Undefined