• FUNC 1
Bit
7
Undefined
6
5
4
3
Download execute condition (RDC):
0: No job in memory
1: Anytime
2
Remote access user setting:
0: Disable
1: Enable
1
EOL (End of Line) Timer Value:
0
00: 5sec.
01: 6sec.
10: Undefined
11: 13sec.
<Remarks>
FUNC 1 Bit 3:
Upgrading (changing) the firmware normally clears all the Pending Jobs remained in the memory.
Refer to page 1-105.
FUNC 1 Bit 2:
Set whether or not the remote access user setting.
Refer to page 1-104.
FUNC 1 Bits 1 and 0:
These bits indicate the setting of the EOL (End of Line) check timer in high-speed image data.
Note: EOL is the code that is put between lines. If the next EOL is not detected within the time
specified in this setting, the line is disconnect due to communication error.
GD-1060 ADJUSTMENT ITEMS
Contents
1 - 12
Link with User
Function Setting
Yes
Yes
January 2001 © TOSHIBA TEC