• FUNC 7
Bit
7
CI-ON Determine Time:
6
00: 175 ms
01: 125 ms
10: 800 ms
11: 145 ms
5
CI-OFF Determine Time:
4
00: 500 ms
01: 350 ms
10: 175 ms
11: 90 ms
3
Undefined
2
Undefined
1
0
<Remarks>
FUNC 7 Bits 7 and 6:
These bits program call signal ON time. When CI cannot be received, the value should be changed.
FUNC 7 Bits 5 and 4:
These bits program call signal OFF time.
GD-1060 ADJUSTMENT ITEMS