Toshiba GD-1060 Service Handbook page 6

Hide thumbs Also See for GD-1060:
Table of Contents

Advertisement

Code
Maintenance
User
Dialing and redialing was attempted
50
50
as many as the specified count but the
line was busy.
The password did not match in a Re-
53
53
lay or Mailbox transmission, and the
transmission ended in failure.
DIS (GI) could not detected.
B0
80
DIS/NSF that cannot be handled by
B1
82
the sender is received.
The receiver received NSS/DCS other
than those declared by DIS/NSF.
DCN is received.
B2
82
DCS/DTC was not detected.
B3
80
The sender performed fall-back but the
B4
82
transmission was not enabled. The re-
ceiver was not detect TCF or detected
DCN after sending FTT.
CFR (FTT) was not detected.
B5
80
Image signal carrier was not detected.
C0
85
High-speed signal was not detected
C1
83
on the receiving side.
January 2001 © TOSHIBA TEC
Cause
Confirm the phone numbers of the re-
mote party.
Confirm that both parties are using the
same system password and the both
units are compatible. Then, ask the re-
mote party to transmit again.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
This may happen in some cases of bad
line condition. Attempt the transmission
again or ask the remote party to attempt
the transmission again.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
This may happen in some cases of bad
line condition. Attempt the transmission
again. Or ask the remote party to attempt
the transmission again.
This may happen in some cases of bad
line condition. Attempt the transmission
again.
This may happen in some cases of bad
line condition. Ask the remote party to
transmit again.
This may happen in some cases of bad
line condition. Ask the remote party to
transmit again.
1 - 3
Remedy
GD-1060 ADJUSTMENT ITEMS