Make sure to specify an IP address that is in the same subnet as the Dante network for the
SLOT IP. The following IP addresses cannot be used for the STATIC IP of the SLOT IP
SETTING.
192.168.53.xxx /24
172.17.xxx.xxx /16 - 172.24.xxx.xxx/16
(These are reserved for RIVAGE PM systems.)
169.254.xxx.xxx /16 (Link-local addresses) *1
Multicast addresses
Use an IP address in a different subnet from the IP address assigned to the DSP ENGINE
IP SETTING.
To use multiple HY144-D/-SRC cards, specify the Dante Control ID. Set a unique ID to each
card (except for ID OFF).
Example 2: Multiple Dante networks
AUTO IP Setting
The AUTO option automatically determines the Primary/Secondary IP and SLOT IP for the
Dante device. Make sure that the Primary/Secondary IP and SLOT IP for each Dante device
is set to AUTO (DHCP) – which is the default.