Section 2 Specifications

Specifications are subject to change without notice.
Specification
Dimensions (L x W x H)
Weight
Enclosure rating
Power requirements
(internal)
Power requirements
(external)
Meter protection class
Operating temperature
Charging temperature
Operating humidity
Storage temperature
Probe connector
Micro-USB connector
Data log (internal)
Data storage
Data export
Temperature correction
Certifications
Warranty

Section 3 General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer's website.
4 English
Details
22 x 9.7 x 6.3 cm (8.7 x 3.8 x 2.5 in.)
HQ1110, HQ1130, HQ1140 and HQ2100: 519 g (18.3 oz); HQ2200:
541 g (19.1 oz); HQ4100: 530 g (18.7 oz); HQ4200: 550 g (19.4 oz);
HQ4300: 570 g (20.1 oz)
IP67 with battery compartment installed
Rechargeable lithium-ion battery 18650 (18-mm diameter x 65-mm
length, cylindrical), 3.7 VDC, 3400 mAh; Battery Life: > 1 week with
typical use (10 readings/day, 5 days/week in Continuous or Push to
read mode, or > 24 hours in Interval mode with 5 minute intervals and
shutdown timer ≤ 15 minutes)
Class II, USB power adapter: 100–240 VAC, 50/60 Hz input; 5 VDC at
2 A USB power adapter output
IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered);
USB power adapter is IEC Class II (double-insulated)
0 to 60 °C (32 to 140 °F)
10 to 40 °C (50 to 104 °F)
90% (non-condensing)
–20 to 60 °C (–4 to 140 °F) maximum 90% relative humidity (non-
condensing)
5-pin M12 connector for Intellical probes
The micro-USB connector enables USB cable and USB power
adapter connectivity.
HQ1000 Series: 5000 data points; HQ2000 Series: 10,000 data
points; HQ4000 Series: 100,000 data points
Automatic storage in Push to read and Interval modes. Manual
storage in Continuous mode.
USB connection to PC or USB storage device (limited to the storage
device capacity)
Off, automatic and manual (parameter-specific)
CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy
Efficiency, RoHS
HQ1000 and HQ2000 series: 1 year (US), 2 years (EU);
HQ4000 series: 3 years (US), 3 years (EU)