CommScope ADCP-90-326 User Manual
CommScope ADCP-90-326 User Manual

CommScope ADCP-90-326 User Manual

Fiber management tray-d (fmt-d)

Advertisement

Quick Links

ADCP-90-326 • Rev B • November 2020
www.commscope.com
Fiber Management Tray-D (FMT-D
Content
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Trademark Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
ADMONISHMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1
PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3
UNPACKING THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4
MOUNTING THE FMT ON THE RACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5
INSTALLING VERTICAL CABLE GUIDES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6
INSTALLING AND ROUTING CABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.1
6.2
6.3
ADCP-90-326 Rev B
Fiber Management Tray
Routing and Securing Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Attenuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Termination Only FMT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.3.1
24-Position Termination Only Tray, Universal Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.3.2
32-Position Termination Only Tray, Universal Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
User
Manual
)
20250-A
Page
(continued)
Page 1
© 2020, CommScope Inc.

Advertisement

Table of Contents
loading

Summary of Contents for CommScope ADCP-90-326

  • Page 1: Table Of Contents

    User Manual ADCP-90-326 • Rev B • November 2020 www.commscope.com Fiber Management Tray-D (FMT-D 20250-A Fiber Management Tray Content Page INTRODUCTION ..................2 Revision History .
  • Page 2: Introduction

    CUSTOMER INFORMATION AND ASSISTANCE........... . .26 INTRODUCTION This manual describes the CommScope Fiber Management Tray-D (FMT-D) and provides all information required to install and use this product.
  • Page 3: Admonishments

    This practice also prevents dirt particles from entering the adapter or connector. 1 PRODUCT DESCRIPTION The CommScope Fiber Management Tray (FMT) is a rack-mount, front-access fiber optic tray available in a variety configurations. Some of these are noted below: •...
  • Page 4 ADCP-90-326 • Rev B • November 2020 Figure 1 shows one of the FMT configurations, the 12-position termination and storage tray. Some of the features common to all FMT configurations are displayed. LOCK OPEN LATCH LEFT REAR RADIUS LIMITERS SLIDING...
  • Page 5: Specifications

    ADCP-90-326 • Rev B • November 2020 • Sliding Adapters Packs—Each with two adapters, provide easy access for connecting cables and cleaning connectors. Product offerings for adapters/connectors include most industry-standard multimode and singlemode types. Figure 2 shows a closed tray with the sliding radius limiter in a closed position. Also shown is the optional lock.
  • Page 6: Unpacking The Product

    ADCP-90-326 • Rev B • November 2020 19-INCH FMT 17.21 IN. (43.7 CM) 11.05 IN. (28.05 CM) TOP VIEW RECESS OPTIONS 40 mm 1.535 IN. 3.9 CM 2.2-INCH 3.07 IN. 7.8 CM 5-INCH 5.0 IN. 12.7 CM 6.5-INCH 6.5 IN.
  • Page 7: Mounting The Fmt On The Rack

    ADCP-90-326 • Rev B • November 2020 3. If damage is detected or if parts are missing, file a claim with the commercial carrier and then notify CommScope Customer Service. Save damaged carton for inspection by the carrier. 4. Refer to...
  • Page 8 ADCP-90-326 • Rev B • November 2020 a. Recess is 40 mm (1.54 inch) or 2.2-inch (5.59 cm), use of VCGs is not advised. b. Recess is 3.1-inch (7.9 cm), 5-inch (12.7 cm), or 6.5-inch (16.5 cm), mount the VCGs on the rack narrow flange using the same screw and hole position as used for the top mounting screw on the panel mounting bracket.
  • Page 9: Installing And Routing Cables

    ADCP-90-326 • Rev B • November 2020 20202-A VERTICAL MOUNTING CABLE GUIDE BRACKET Figure 6. Installing VCGs (23-Inch Rack Mount) 6 INSTALLING AND ROUTING CABLES Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of any optical fiber.
  • Page 10 Figure Note: Install the cable clamp kit following the instructions provided in the installation drawing shipped with the kit. Ribbon blocking kits are available from CommScope in a variety of sizes to match any ribbon cable type. 4. Route the cables into the FMT through the specified sliding radius limiter(s).
  • Page 11 ADCP-90-326 • Rev B • November 2020 CABLE CLAMP AND MOUNTING BRACKET DETAIL OF CABLE TIE-OFF POINT LANCE CABLE CLAMP AND MOUNTING BRACKET PLACE OPTIONAL ATTENUATOR ON THIS SIDE OF SLIDING ADAPTER PACK ROUTE CABLE INTO FMT 20203-A THROUGH SLIDING RADIUS LIMITER Figure 7.
  • Page 12: Attenuators

    ADCP-90-326 • Rev B • November 2020 CABLE CLAMP AND MOUNTING BRACKET DETAIL OF CABLE TIE-OFF POINT RIBBON BLOCKING CABLE CLAMP AND MOUNTING LANCE RIBBON BRACKET CABLE RIBBON BLOCKING PLACE OPTIONAL ATTENUATOR ON THIS SIDE OF SLIDING ADAPTER PACK ROUTE PROTECTIVE...
  • Page 13: 24-Position Termination Only Tray, Universal Entry

    ADCP-90-326 • Rev B • November 2020 Termination Only FMT Configuration Cables routed into the FMT for termination only will typically be pre-terminated individual cables of 2 mm or 3 mm diameter. Refer to the following instructions. 6.3.1 24-Position Termination Only Tray, Universal Entry...
  • Page 14: 32-Position Termination Only Tray, Universal Entry

    ADCP-90-326 • Rev B • November 2020 6.3.2 32-Position Termination Only Tray, Universal Entry Route and install the cables as shown in Figure 10. Place kurly locks at locations indicated. ROUTE FIBERS ALONG THE SOLID ARROW ON INDICATED PATH, THEN FOLLOW THE APPROPRIATE DOTTED LINE.
  • Page 15: 12-Position Termination And Storage Tray, Universal Storage

    ADCP-90-326 • Rev B • November 2020 Termination and Storage FMT Configuration Cables routed into the FMT for termination and storage will typically be pre-terminated individual cables of 2 mm or 3 mm outside diameter. For instructions on routing the cables within the tray, select from the subsections below based on the tray configuration being installed.
  • Page 16: 16-Position Termination And Storage Tray, Universal Storage

    ADCP-90-326 • Rev B • November 2020 6.4.2 16-Position Termination and Storage Tray, Universal Storage Route and install the cables as shown in Figure 12. Place kurly locks at locations indicated. ROUTE FIBERS ALONG THE SOLID ARROW ON INDICATED PATH, THEN FOLLOW THE APPROPRIATE DOTTED LINE.
  • Page 17: 24-Position Termination And Storage Tray, Left/Right Storage

    ADCP-90-326 • Rev B • November 2020 6.4.3 24-Position Termination and Storage Tray, Left/Right Storage Route and install the cables as shown in Figure 13. The figure shows a left-storage configuration with sliding adapter packs. For a right-entry storage, the routing is a mirror image of what is shown.
  • Page 18: Bulk Storage Only Fmt Configuration

    ADCP-90-326 • Rev B • November 2020 Bulk Storage Only FMT Configuration Note: The number and length of cables that can be stored in a bulk storage tray depends on the cable dimension (refer to Table 1 on page Route and install the cables as shown in Figure 14.
  • Page 19: 12-Position Termination And Splice Tray

    ADCP-90-326 • Rev B • November 2020 12-Position Termination and Splice Tray Note: Splicing instructions are not included. For splicing instructions, follow local practice. Termination and splice trays provide 12 termination and splice positions. Install the cables for a 12-position termination and splice tray as follows: 1.
  • Page 20 ADCP-90-326 • Rev B • November 2020 TIE OFF CUSTOMER FIBER BUNDLE TO SLIDING ADAPTER PACKS PRE-TERMINATED CUSTOMER FIBER BUNDLE FIBER BUNDLE SPLICE TRAY 20344-A Figure 16. Cable Routing for 12-Position Termination and Splice Tray, Step 2 Page 20 © 2020, CommScope Inc.
  • Page 21 ADCP-90-326 • Rev B • November 2020 TIE OFF CUSTOMER FIBER BUNDLE LOOP THREE TIMES TO SLIDING ADAPTER PACKS CUSTOMER PRE-TERMINATED FIBER BUNDLE FIBER BUNDLE TIE OFF POINT TIE OFF POINT CUSTOMER FIBER PRE-TERMINATED FIBER SPLICE TRAY PRE-TERMINATED CUSTOMER FIBER...
  • Page 22 ADCP-90-326 • Rev B • November 2020 TIE OFF CUSTOMER FIBER BUNDLE TO SLIDING ADAPTER PACKS 20346-A Figure 18. Cable Routing for 12 Termination and Splice Tray, Step 4 TIE OFF CUSTOMER CUSTOMER PATCHCORDS FIBER BUNDLE KURLY LOCK (3 PLACES) 20205-A Figure 19.
  • Page 23: Operation

    ADCP-90-326 • Rev B • November 2020 7 OPERATION The term “operation” refers to procedures performed on an ongoing basis after the FMT is installed. The only FMT trays that require operation are those having a termination function. Patch cords may be installed in such trays for use in connecting or testing equipment. When...
  • Page 24: Accessing Sliding Adapter Packs

    ADCP-90-326 • Rev B • November 2020 Accessing Sliding Adapter Packs Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical adapters of the adapter packs.
  • Page 25: Accessing Bulkhead Plate Adapters

    ADCP-90-326 • Rev B • November 2020 Accessing Bulkhead Plate Adapters Danger: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical adapters of the adapter packs.
  • Page 26: Customer Information And Assistance

    ADCP-90-326 • Rev B • November 2020 8 CUSTOMER INFORMATION AND ASSISTANCE For general product information, visit our website: http://www.commscope.com For technical assistance, contact the CommScope Support Center using the following URL: http://www.commscope.com/SupportCenter For information on patents, go to http://www.cs-pat Page 26 ©...

Table of Contents