Elster themis plus Operating Instructions For Consumers

Elster themis plus Operating Instructions For Consumers

Electronic index for diaphragm gas meters

Advertisement

0500/00 · Edition .
www.docuthek.com
D
GB
I
 
Operating instructions
for consumers
Electronic index for
diaphragm gas meters BK..B
Translation from the German
© 2013 Elster GmbH
Contents
Contents
Electronic index for
diaphragm gas meters BK..B . . . . . . . . . . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating the electronic index . . . . . . . . . . . . 
Navigating within the menu . . . . . . . . . . . . . . 
Electrical pulse output. . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 6
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Safety
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• ,  ,  ,  ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Transport
On receipt of the product, check that the delivery is
complete see page 2 (Part designations). Report
any transport damage immediately.
Storage
Store the product in a dry place. Ambient tempera-
ture: see page 6 (Technical data).
Changes to edition 08.
The following chapters have been changed:
-
Checking the usage
-
Navigating within the menu
GB-1

Advertisement

Table of Contents
loading

Summary of Contents for Elster themis plus

  • Page 1: Table Of Contents

    Safety instructions Information that is relevant for safety is indicated in the instructions as follows: Translation from the German DANGER © 2013 Elster GmbH Contents Contents Indicates potentially fatal situations. Electronic index for WARNING diaphragm gas meters BK..B ... . . ...
  • Page 2: Checking The Usage

    ATEX Checking the usage ▷ The electronic index is suitable for use in po- Electronic index EI for diaphragm tentially explosive atmospheres. For the exact gas meters BK..B use (zone), see ATEX sticker on the diaphragm The electronic index EI3 indicates the volume at base gas meter or see “Operating instructions for conditions.
  • Page 3: Navigating Within The Menu

    User keys, selection key and symbols Menu overview ▷ You can navigate through the menu using the user keys and the selection key Symbol Meaning Navigate to the left or the right on each level using the user keys. – Briefly pressing the selection key selects Current meter reading General instructions...
  • Page 4 ▷ By briefly pressing the selection key, you can Past meter readings ▷ Consumption data dating as far back as visualize the consumption data. 20  weeks can be called up. Consumption results ▷ By pressing the selection key , consumption data are displayed, which are given by month, F01: 0.00m...
  • Page 5: Electrical Pulse Output

    Assistance in the event of Billing information (1/5) malfunction Vb : 4.00 m F01 : 0.00m ? Fault F02 : 0.00m ! Cause F03 : 0.00m • Remedy UES :0x0240000000000000 Possible faults and suggested solutions ? The symbol is displayed. ▷...
  • Page 6: Technical Data

    Temperature measurement accuracy on the day of certified as parts of the electronic index. Use only manufacture: spare parts from Elster. ± 0.2°C in the range from -10 to +55°C. The electrical interfaces feature the following ± 0.25°C in the range from -25 to -10°C.
  • Page 7 GB-7...
  • Page 8: Contact

    Contact Contact United Kingdom Elster Metering Limited Paton Drive Tollgate Business Park Beaconside Stafford, ST16 3EF T +44 1785 275200 F +44 1785 275305 jeavons.info@gb.elster.com www.elstermetering.co.uk Ireland Germany Active Energy Control Ltd. Elster GmbH Unit 4, Clare Marts Strotheweg 1...