“product”) are the result of targeted development and meticulous research. From the date of delivery, burster provides a warranty for the proper condition and functioning of these products covering material and production defects for the period specified in the warranty document accompanying the product.
Contents For your safety ............................. 6 Symbols used in the operating manual ..................6 1.1.1 Signal words ........................6 1.1.2 Pictograms ........................6 Introduction ............................7 Intended use ..........................7 2.1.1 Customer service department ..................7 2.1.2 Contact person ......................... 7 Download the test certificate ......................
Property damage to the equipment or the surroundings will result if the hazard is not avoided. Note: It is important to heed these safety notices in order to ensure you handle the model 8524 tension and compression load cell correctly.
Intended use The load cells in the 8524 model series are primarily designed for the measurement of force in production equipment, using newtons (N) as the unit of measurement. The local gravitational acceleration (g ≈ 9.81 m/s²) must be taken into account when determining masses.
EN 61558. 2.3.3 Restrictions on use The model 8524 tension and compression load cell does not pose a hazard if used within its specification and in accordance with the safety regulations.
Inspect the model 8524 tension and compression load cell for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours.
Only the manufacturer’s own qualified personnel are permitted to open the model 8524 tension and compression load cell. It is not permitted to make any changes to the model 8524 tension and compression load cell without the written agreement of burster präzisionsmesstechnik gmbh & co kg. burster präzisionsmesstechnik gmbh &...
Concept and general information Please refer to the data sheet for the model 8524 precision tension and compression load cell for full details of dimensions, weight, degree of protection etc. Mechanical design In the model 8524 tension and compression load cell, the spring element is designed as a horizontally oriented elastic membrane with a centrally arranged ring.
: Reference excitation voltage • c: Rated output of the sensor You can find the rated output “c” on the test certificate for the model 8524 tension and compression load cell. It is typically in the region of 1.5 mV/V ±0.25%.
3.2.3 Overload protection burster offers the model 8524 tension and compression load cell optionally with mechanical overload protection for compressive loads up to a measuring range of 0 ... 20 kN (option 8524-XXXX-XXXXX4XX overload protection unidirectional in direction of compression).
Note: Transmitters connected to the outputs or other devices that are galvanically connected to the signal lines of the model 8524 tension and compression load cell must also be fitted with safety transformers to EN 61558. Grounding and equipotential bonding All connecting wires (including the cable screening braid) are electrically insulated from the sensor body.
Prevent torsional moments, lateral forces and bending forces. Application of force 1. Apply the force being measured to the model 8524 tension and compression load cell via the central thread. 2. Apply the force centrically exactly along the axis of symmetry.
8524 tension and compression load cell is used as a weighing device on containers. Fixing method The entire contact surface of the model 8524 tension and compression load cell must lie on a hardened (60 HRC), flat, ground or lapped mounting surface. Bolts...
5.3.1 Connector pin assignment The model 8524 tension and compression load cell is supplied with an open cable end. The model 8524 tension and compression load cell is optionally fitted with connectors for burster display and calibration equipment.
Wire colors for model 8524 tension and compression load cell with open cable ends Figure 7: Wire colors for model 8524 tension and compression load cell Description for Figure 7: *: Only with extended cable over 5 m in length **: Optional 5.3.1.1...
5.3.1.2 Option 8524-xxxx-xxTxxxxx Connection to burster devices with 9-pin D-sub socket with 6-wire system with burster TEDS. Figure 10: Device connection Figure 11: Connection to 9-pin burster TEDS 5.3.1.3 Option 8524-xxxx-xxExxxxx Connection to burster devices with 9-pin D-sub socket with 4-wire system for 9163-V3xxx.
Measurement chain calibration Each model 8524 tension and compression load cell is supplied with an individual test and calibration certificate. You can also download this test and calibration certificate at a later date by entering the serial number on the burster website (www.burster.com) The downstream electronics must always be calibrated for the respective model 8524 tension and compression load cell.
Technical data Please refer to the enclosed data sheet for the technical specification. The latest version of the data sheet is available at: https://www.burster.de/en/sensors/load-cells/tension-and-compression-load- cells/p/detail/8524 or simply use the following QR code: Figure 18: Technical data QR code Electromagnetic compatibility 7.1.1 Interference immunity...
Accessories available Please refer to the enclosed data sheet for details of the accessories available. The latest version of the data sheet is available at: https://www.burster.de/en/sensors/load-cells/tension-and-compression-load- cells/p/detail/8524 or simply use the following QR code: Figure 19: Accessories available of 24...
Disposal Instrument disposal If your instrument is no longer usable, please comply with your legal obligations by disposing of the instrument described here in accordance with statutory regulations. You will then be helping to protect the environment! of 24...
Need help?
Do you have a question about the 8524 and is the answer not in the manual?
Questions and answers