The following parameters can be adjusted with the DIP switch:
DIP switch
Sense a
Sense b
Sense a
Sense b
Sense a
Sense b
Sense a
Sense b
Frequency
Hold time
Output 2
Edge 2
Inv. Out 1
Inv. Out 2
Tab. 12: Settings via DIP switch (single-channel)
The dual-channel variants have an 8-pole and 4-pole DIP switch for configuring the detector.
DIP1
Designation
1
Sense 1a
2
Sense 1b
3
Sense 2a
4
Sense 2b
5
Frequency
6
Hold time
7
Output 2
8
Edge 2
Tab. 13: DIP switch 1 assignment (standard)
VEK MNH Operating Manual v1.3 en
Position
Value
ON
0.01% (high)
ON
OFF
0,04%
ON
ON
0,16%
OFF
OFF
0.64% (low)
OFF
OFF
low
ON
high
OFF
5 minutes
ON
Infinite
OFF
Continuous signal
ON
Pulse signal
OFF
on entering
ON
on leaving
OFF
inverted
ON
not inverted
OFF
not inverted
ON
inverted
Function
Loop 1 sensitivity
Loop 1 sensitivity
Loop 2 sensitivity
Loop 2 sensitivity
Frequency level
Hold time until readjustment
Output signal 2 mode
Output signal 2 time