Operating instructions Traffic detector VEK M2E-2 FEIG ELECTRONIC GmbH Lange Straße 4 35781 Weilburg/Lahn...
Page 2
Composition of the information given in this manual has been done to the best of our knowledge. FEIG ELECTRONIC does not guarantee the correctness of the details given in these instructions and may not be held liable for damages ensuing from incorrect installation.
Structural shape: • Housing 76x38x71mm (HxWxL) with 11-pole circular connector, RAL 5005 • 2 boards, 72x65mm each For planning and installation of induction loops, please refer to our manual „vehicle detection with the induction loop detector“. 03/06 FEIG ELECTRONIC GmbH...
5 minutes Infinite After the holding time has expired, the "loop free" signal is indicated and the loops will be automatically readjusted. The holding time of a detector channel starts with the assignment of the respective loop. FEIG ELECTRONIC GmbH 03/06...
1 2 . a) Single vehicle DIP-switch 8 "ON" DIP-switch 8 "OFF" pulse signal permanent signal Relay 1 Relay 1 directional pulse permanent direction signal 'on' Relay 1 permanent direction signal 'remains' Relay 1 permanent direction signal 'off' 03/06 FEIG ELECTRONIC GmbH...
Page 7
'remains' Relay 1 permanent direction signal 'remains' Relay 1 permanent direction signal 'off' Relay 1 Relay 1 directional pulse permanent direction signal 'on' Relay 1 permanent direction signal 'remains' Relay 1 permanent direction signal 'off' FEIG ELECTRONIC GmbH 03/06...
Due to this, the following vehicles will again be detected. Longer adjustment times hint to an unstable loop frequency. The loop/detector system has to be checked with regard to possible interferences. 03/06 FEIG ELECTRONIC GmbH...
After the fault has been eliminated, the detector channel keeps on working independently. The green LED pulsates now, in order to hint to the fault which has occurred and already been eliminated. This fault indicator is restored by pressing the reset key. FEIG ELECTRONIC GmbH 03/06...
1kHz-position is a little shorter than the one of the 10kHz- position. Example of a 57kHz loop frequency: Zehner Einer 5x 10kHz 7x 1kHz entspricht: 57kHz If both channels are adjusted at the same time, the frequency of channel 1 is indicated before channel 2. 03/06 FEIG ELECTRONIC GmbH...
Mixed operation of extra-low- and low voltage at the relays is not admitted ! ( e.g. 24VDC at relay 1 and 230VAC at relay 2 ). The durability of the relay contacts is increased by external, parallel connected RC modules (e.g. 100Ohm/10nF)! 03/06 FEIG ELECTRONIC GmbH...
• The device is intended for installation in a switch cabinet. The switch cabinet has to have a continuous base isolation. Installation of this device outside a switch cabinet-like housing is not admitted. FEIG ELECTRONIC GmbH 03/06...
8. Device categories In the following, we will deal with the differences between the various types in comparison to standard model VEK M2E-2-A. 8.1. Type VEK M2E-2 -B Contact assignment type VEK M2E-2-B: 230V Notice: 50-60Hz N Relay contacts are pictured in idle condition ! No mixed operation of extra-low- and low voltage at the relays! ( e.g.
Directional logic type VEK M2E-2-E: a) single vehicle DIP-switch 8 "ON" DIP-switch 8 "OFF" pulse signal permanent signal Relay 1 permanent direction signal 'on' Relay 1 Relay 1 directional pulse permanent direction signal 'remains' Relay 1 permanent direction signal 'off' FEIG ELECTRONIC GmbH 03/06...
Page 16
In case of a loop failure, the green LED of the disturbed channel will flash in short intervals ! • In „presence detection“ position, the red LED will light up during a loop failure or readjustment of channel 1! 03/06 FEIG ELECTRONIC GmbH...
• According to machine directive 89/392/EWG, appendix IV, the appliance must not be used as a safety component. Systems with a high danger potential need additional safety contrivances ! FEIG ELECTRONIC GmbH 03/06...