Specifications
Inputs
1 x loop (1 x orange, single-channel variants)
2 x loop (1 x orange, dual-channel variants)
Outputs
2 x relays (1 x yellow, 1 x red, R24 variants)
4 x open collector (2 x green, O24 variants)
Configuration switch 1 (all variants)
Configuration switch 2 (dual-channel variants)
LED status indicator
Reset button
PC interface
Tab. 6: Specifications
NOTE
1) Limitations on loop inductance
For loop inductances outside the recommended range, only one frequency level may be available.
For very small loop inductances, the maximum loop resistances are lower.
2) Current load of the relay contacts
The rigid gold plating on the relay contacts will be destroyed if the switching current exceeds 100
mA. Relays with contacts that are prestressed in this manner can only reliably switch currents over
100 mA!
3) Terminal block data
Grid dimension 5.0 mm, conductor cross-section 0.25 - 2.5 mm², AWG 24-12
VEK MNH Operating Manual v1.3 en
2-pole terminal block (see Note 3)
4-pole terminal block (see Note 3)
3-pole terminal block (see Note 3)
Max. 48 V (AC/DC), 2 A, 60 W, 125 VA (SELV)
Min. 1 mA / 5 V (see note 2)
3-pole terminal block (see Note 3)
27 V DC, 25 mA (SELV)
8-pole DIP switch
4-pole DIP switch
1 x blue and 1 x red (per loop channel)
Push button
USB port, type mini AB
18 | 56