Service functions

10
Service functions
10

Reset / Cold start

.01
After selecting the Reset menu, by pressing the relevant plus key it is possible to delete
seam parameters and seam programs or to carry out a cold start.
A+
A+
1 = Reset seam parameters
2 = Reset seam programs
3 = Cold start
56
Press and hold plus-minus keys "A+" and "D+" and switch on the machine.
Select Reset
1
2
B+
Press plus key "A+".
All seam parameters are deleted, the message "MASTER-RESET 1" appears briefl y
on the display.
Press plus key "B+".
All seam programs are deleted, the message "MASTER-RESET 2" appears briefl y on the
display.
Press plus key "D+".
The values of the machine control unit, except the machine class, are set back to their
basic values. The message "COLD START" appears briefl y on the display.
After the cold start all programmed values are set back to their status at the
time of delivery. For this reason, after a cold start the parameters 799, 800 and
700 must by checked and reset if necessary.
3
D+
D+